40
Cut Out Data with Registration Mark
No-plotting area around the registration marks
An area around a registration mark (from the mark origin to the mark size area) is a non-plotting area. There
must be no data plotted or stain in this area; otherwise, a wrong origin may be detected or a mark read error
can occur.
Example of cause of wrong detection 1
There is a line outside the registration marks
Example of cause of wrong detection 2
The distance between registration marks
(TP2 and TP1 or TP4 and TP2) is smaller
than the mark length (for Type 2)
• If a wrong mark origin is detected, the cutting will be performed in a wrong area.
Mark size
Mark Form : Type 1
No-plotting area
Mark
Mark Origin
No-plotting area
Mark
Mark Origin
Mark Form : Type 2
No-plotting area
Mark Origin
Detected wrong
mark origin
Space larger than
the mark length
Space larger than
the mark length