background image

14

  MI605 Dissolved Oxygen Meter

MANMI605 07/20-1

CERTIFICATION

Milwaukee Instruments conform to the CE European Directives.

 

RoHS

COMPLIANT

Disposal of Electrical & Electronic Equipment.

 Do not treat this product 

as household waste. Hand it over to the appropriate collection point for 

the recycling of electrical and electronic equipment.

Disposal of waste batteries.

 This product contains batteries. Do not 

dispose of them with other household waste. Hand them over to the 

appropriate collection point for recycling.

Please note: proper product and battery disposal prevents potential 

negative consequences for human health and the environment. For 

detailed information, contact your local household waste disposal 

service or go to 

www.milwaukeeinstruments.com

 (US only) or 

www.milwaukeeinst.com

.

RECOMMENDATION

Before using this product, make sure it is entirely suitable for your specific 

application and for the environment in which it is used. Any modification 

introduced by the user to the supplied equipment may compromise the 

meter’s performance. For your and the meter’s safety do not use or store 

the meter in hazardous environment. To avoid damage or burn, do not 

perform any measurement in microwave ovens.

WARRANTY

These instruments are warranted against defects in materials and 

manufacturing for a period of 2 years from the date of purchase. 

Electrodes and Probes are warranted for 6 months. This warranty is 

limited to repair or free of charge replacement if the instrument cannot 

be repaired. Damage due to accidents, misuse, tampering or lack of 

prescribed maintenance is not covered by warranty. If service is required, 

contact your local Milwaukee Instruments Technical Service. If the 

repair is not covered by the warranty, you will be notified of the charges 

incurred. When shipping any meter, make sure it is properly packaged for 

complete protection. 

Содержание MI605

Страница 1: ...INSTRUCTION MANUAL SATISFACTION GUARANTEED MI605 Dissolved Oxygen Meter...

Страница 2: ...is prohibited without the written consent of the copyright owner Milwaukee Instruments Inc Rocky Mount NC 27804 USA THANK YOU for choosing Milwaukee Instruments This instruction manual will provide yo...

Страница 3: ...AL OPERATIONS 4 4 PROBE PREPARATION 5 5 PROBE POLARIZATION 6 6 MEASUREMENTS 7 7 ALTITUDE COMPENSATION 8 8 SALINITY COMPENSATION 9 9 CALIBRATION PROCEDURE 10 10 PROBE MEMBRANE MAINTENANCE 11 11 BATTERY...

Страница 4: ...m resolution SALINITY COMPENSATION 0 to 80 g L 1 g L resolution PROBE MA840 included ENVIRONMENT 0 to 50 C 100 RH max BATTERY TYPE 1 x 9V alkaline included BATTERY LIFE approx 100 hours of use AUTO O...

Страница 5: ...ied with the meter with electrolyte while shaking it gently Refill with clean electrolyte 4 Gently tap the sides of the membrane with the finger tip to ensure that no air bubbles remain trapped To avo...

Страница 6: ...consumed by passing through the sensitive diaphragm and dissolving in the electrolyte solution inside the probe If this operation is interrupted the electrolyte solution continues to be enriched with...

Страница 7: ...e not possible while the liquid is at rest During laboratory measurements the use of a magnetic stirrer to ensure a certain velocity in the fluid is recommended In this way errors due to the diffusion...

Страница 8: ...7 12 2 11 9 11 4 11 0 10 6 39 2 6 12 4 12 0 11 6 11 2 10 8 10 4 10 1 42 8 8 11 8 11 4 11 0 10 6 10 3 9 9 9 6 46 4 10 11 3 10 9 10 5 10 2 9 8 9 5 9 2 50 0 12 10 8 10 4 10 1 9 7 9 4 9 1 8 8 53 6 14 10...

Страница 9: ...matically compensate for salinity effects see also following table for verification C Salinity g l at Sea Level F 0 g l 10 g l 20 g l 30 g l 35 g l 10 11 3 10 6 9 9 9 3 9 0 50 0 12 10 8 10 1 9 5 8 9 8...

Страница 10: ...nditioning mode automatic polarization y Once COND disappears the probe is polarized and the instrument can be calibrated y Remove the probe protective cap y Press CAL appears on the larger LCD togeth...

Страница 11: ...ntly tap the sides of the membrane with the finger tip to ensure that no air bubbles remain trapped Do no directly tap the bottom with the finger as this will damage the membrane y Makesurethattherubb...

Страница 12: ...ts from the environment but allows oxygen to enter If any dirt is observed on the membrane rinse it carefully with distilled or deionized water If any imperfections still exist or any damage is eviden...

Страница 13: ...y life remain A low battery will result in unreliable measurements It is recommended to replace the battery immediately by using an alkaline 9V battery Turn the meter off unscrew the two screws on the...

Страница 14: ...duct makesureitisentirelysuitableforyourspecific application and for the environment in which it is used Any modification introduced by the user to the supplied equipment may compromise the meter s pe...

Страница 15: ...MilwaukeeInstrumentsreservestherighttomakeimprovementsindesign construction and appearance of its products without advance notice...

Страница 16: ...C H 6726 Szeged HUNGARY tel 36 62 428 050 fax 36 62 428 051 www milwaukeeinst com e mail sales milwaukeeinst com Milwaukee Instruments Inc 2950 Business Park Drive Rocky Mount NC 27804 USA tel 1 252 4...

Отзывы: