18

ENGLISH

BASIC DESCRIPTION ON EXAMPLE OF AREA MEASURING (2)

6

 View stored values

Push button 

 2 sec.

Push button 

 repaeted

7

 Exit memory

Push button 

.

8

 Switch off

Push button 

 2 sec 

(Memory must be exited before)

 

- Stored values appears in the 

main line.

 

- Associated icon appears and 

measured parameter fl ashes 

(fl ashing green illustrated)

 

- Device switches off.

 

- If no button is pressed, the device 

switches off automatically after 3 

minutes.

Содержание LDM50

Страница 1: ...before use Always store the laser distance measurer indoors avoid exposing the tool to shock continuous vibration or extreme temperatures Always keep the tool away from dust liquids and high humidity...

Страница 2: ...s Operating Temperature Range 10 C to 50 C Storage Temperature Range 25 C to 70 C Weight without Battery 80 g SPECIFIED CONDITIONS OF USE The laser distance measurer can be used for measuring distance...

Страница 3: ...oras 1 push 1x Pythagoras 2 push 2x Pythagoras 3 push 3x MEMORY Timer 3 15 sec push 1x Memory 1 20 push 1x 2 sec Read memory push repeated CHANGE POINT OF MEASURE Front Back Standard automatical Corne...

Страница 4: ...4 1 2 3 1 3 2 2x AAA click ENGLISH ENGLISH CHANGE BATTERIES CORNER PIN Change batteries when battery symbol is ashing BELT CLIP...

Страница 5: ...5 90 90 90 ENGLISH FUNCTION SWITCH MEASURING REFERENCE PYTHAGORAS Area Starting Point of Measure Pythagoras 1 Front Back Standard automatical Corner Pin Pythagoras 2 Pythagoras 3 Volume Wall Distance...

Страница 6: ...6 0 1 2 3 4 5 1 3 5 ENGLISH SINGLE DISTANCE MEASURING...

Страница 7: ...7 0 1 2 3 4 2 sec Stop MIN MAX MIN MAX MAX 2 sec 90 2 ENGLISH PERMANENT MINIMUM MAXIMUM MEASURING...

Страница 8: ...8 0 1 2 3 1 3 1 000 m 1x 2x ENGLISH ADD SUBTRACT MEASURING...

Страница 9: ...9 1 2 1 x 0 1 2 ENGLISH AREA MEASURING...

Страница 10: ...10 1 3 2 2 x 0 1 2 3 ENGLISH VOLUME MEASURING...

Страница 11: ...11 0 1 2 2 1 90 1 x ENGLISH INDIRECT MEASURING PYTHAGORAS 1...

Страница 12: ...12 0 1 2 3 2 x 90 1 3 2 ENGLISH INDIRECT MEASURING PYTHAGORAS 2...

Страница 13: ...13 1 2 3 4 1 2 3 90 3 x ENGLISH INDIRECT MEASURING PYTHAGORAS 3...

Страница 14: ...14 0 1 2 3 3 x 4 5 1 2 3 4 5 ENGLISH WALL AREA MEASURING SCENARIO 1...

Страница 15: ...15 0 1 2 3 4 x 4 5 3 4 5 1 2 ENGLISH WALL AREA MEASURING SCENARIO 2...

Страница 16: ...button Push button The seconds are counted down until the measurement starts At 0 the measurement starts The measured values are stored continuously and automatically in memory The stored values can b...

Страница 17: ...Level the device and push button Lasericon ashes ashing green illustrated Icon is displayed Icon appears Measured parameter ashes ashing green illustrated Measured value appears brie y in the main li...

Страница 18: ...repaeted 7 Exit memory Push button 8 Switch off Push button 2 sec Memory must be exited before Stored values appears in the main line Associated icon appears and measured parameter ashes ashing green...

Отзывы: