SPECIFICATIONS

Cat. No.

Volts

Amps

No Load RPM

Blade Size

Round Arbor

Depth of Cut

6370-20
6370-21

120 AC
120 AC

15
15

3700
3700

8"
8"

5/8"
5/8"

0 to 2-9/16"
0 to 2-9/16"

FUNCTIONAL DESCRIPTION

SYMBOLOGY

* See "Applications" for requirements when cutting thicker 

materials.

CAPACITIES

Materials *

Capacity

Steel Studs, 
Steel Decking, 
Roofi ng Panels

10 gauge,

up to 2-9/16" thick

Steel Plate

1/4" thick

Angle Iron

2-1/2" x 2-1/2" x 1/4"

1. Handle
2. Trigger
3. Chip 

container

4. Sight 

line

5.  Rip fence slot
6. Blade
7.   Lower guard
8. Shoe
9.  Chip viewing window
10. Spindle lock button 
11. Front handle
12. Lower guard lever
13. Overload protector
14. Depth setting gauge 
15. Depth adjusting lever

3

2

1

9

8

7

6

5

4

14

15

16

13

12

10

11

17

22

19

20

18

23

21

3

16. Hex wrench
17. Contact window
18. Latch
19. Upper guard

20. Tab
21. Tab pin
22. Outer blade fl ange
23. Blade bolt

Fig. B Fig. C

Fig. A

GROUNDING

WARNING

 Improperly connecting the 

grounding wire can result in the risk of elec-
tric shock. Check with a qualifi ed electrician 
if you are in doubt as to whether the outlet is 
properly grounded. Do not modify the plug 
provided with the tool. Never remove the 
grounding prong from the plug. Do not use 
the tool if the cord or plug is damaged. If 
damaged, have it repaired by a MILWAUKEE 
service facility before use. If the plug will not 
fi t the outlet, have a proper outlet installed by 
a qualifi ed electrician.

Grounded Tools: Tools with Three Prong Plugs

Tools marked “Grounding Required” have a three 
wire cord and three prong grounding plug. The 
plug must be connected to a properly grounded 
outlet (See Figure A). If the tool should electrically 
malfunction or break down, grounding provides a 
low resistance path to carry electricity away from 
the user, reducing the risk of electric shock.
The grounding prong in the plug is connected 
through the green wire inside the cord to the 
grounding system in the tool. The green wire in the 
cord must be the only wire connected to the tool's 
grounding system and must never be attached to 
an electrically “live” terminal.
Your tool must be plugged into 
an appropriate outlet, properly 
installed and grounded in accord-
ance with all codes and ordinances. 
The plug and outlet should look like 
those in Figure A.

Double Insulated Tools: 
Tools with Two Prong Plugs

Tools marked “Double Insulated” do not require 
grounding. They have a special double insula-
tion system which satisfi es OSHA requirements 
and complies with the applicable standards of 
Underwriters Laboratories, Inc., 
the Canadian Standard Asso-
ciation and the National Elec-
trical Code. Double Insulated 
tools may be used in either of 
the 120 volt outlets shown in 
Figures B and C.

Grounded tools require a three wire extension 
cord. Double insulated tools can use either a two 
or three wire extension cord. As the distance from 
the supply outlet increases, you must use a heavier 
gauge extension cord. Using extension cords with 
inadequately sized wire causes a serious drop in 
voltage, resulting in loss of power and possible tool 
damage. Refer to the table shown to determine the 
required minimum wire size.
The smaller the gauge number of the wire, the 
greater the capacity of the cord. For example, a 14 
gauge cord can carry a higher current than a 16 
gauge cord. When using more than one extension 
cord to make up the total length, be sure each cord 
contains at least the minimum wire size required. 
If you are using one extension cord for more than 
one tool, add the nameplate amperes and use the 
sum to determine the required minimum wire size.

Guidelines for Using Extension Cords

• If you are using an extension cord outdoors, be 

sure it is marked with the suffi x “W-A” (“W” in 
Canada) to indicate that it is acceptable for outdoor 
use.

• Be sure your extension cord is properly wired 

and in good electrical condition. Always replace a 
damaged extension cord or have it repaired by a 
qualifi ed person before using it.

• Protect your extension cords from sharp objects, 

excessive heat and damp or wet areas.

READ AND SAVE ALL 

INSTRUCTIONS FOR FUTURE USE.

* Based on limiting the line voltage drop to fi ve volts at 

150% of the rated amperes.

EXTENSION CORDS

Recommended Minimum Wire Gauge

For Extension Cords*

Nameplate Amps

Extension Cord Length

25'

50'

75'

100'

150'

0 - 2.0

2.1 - 3.4
3.5 - 5.0
5.1 - 7.0

7.1 - 12.0

12.1 - 16.0
16.1 - 20.0

18
18
18
18
16
14
12

18
18
18
16
14
12
10

18
18
16
14
12
10

--

18
16
14
12
10

--
--

16
14
12
12

--
--
--

Some examples of these chemicals are:

 • lead from lead-based paint
  • crystalline silica from bricks and cement and other
  masonry products, and
 • arsenic and chromium from chemically-treated
  lumber.
  Your risk from these exposures varies, depending 

on how often you do this type of work. To reduce 
your exposure to these chemicals: work in a well 
ventilated area, and work with approved safety 
equipment, such as those dust masks that are spe-
cially designed to fi lter out microscopic particles.

Double Insulated

Volts

Alternating Current

Amps

No Load Revolutions per 
Minute (RPM)

C

US

Underwriters Laboratories, Inc.
United States and Canada

Mexican Approvals Marking

Содержание 6370-20

Страница 1: ...Metco Part Number TTi Part Number ECO ECO Date See back page for date code and revisions 58 14 6372 961075229 36277 36927 09 14 2012 12 10 12 39965 02 11 2014 39963 02 11 2014...

Страница 2: ...ATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L UTILISATEUR PARA REDUCIR EL RIESGO DE LESIONES EL USUARIO DEBE LEER Y ENTENDER EL MANUAL DEL OPERADOR OPERATOR S MANUAL MANUEL de L UTILISATEUR MANUAL...

Страница 3: ...he blade Keep your second hand on auxiliary handle or motor housing If both hands are holding the saw they cannot be cut by the blade Do not reach underneath the workpiece The guard cannot protect you...

Страница 4: ...d complies with the applicable standards of Underwriters Laboratories Inc the Canadian Standard Asso ciation and the National Elec trical Code Double Insulated tools may be used in either of the 120 v...

Страница 5: ...and Installing Chip Container and empty Use a brush to ensure all chips and debris have been removed 3 Remove all chips and debris from upper guard blade and housing 4 Replace the chip container see R...

Страница 6: ...shoe as a guide Pocket Cutting Pocket cuts are made in the middle of the workpiece when it can not be cut from an edge We recom mend using a Sawzall reciprocating saw or jig saw for this type of cut H...

Страница 7: ...MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE This warranty applies to product sold in the U S A and Canada only Please consult the Service Center Search in the Parts Service section of MI...

Страница 8: ...e hors de la pi ce coup e vers le haut en direction de l op rateur Lorsque la lame est pinc e ou bloqu e par la fermeture du trait de coupe elle se bloque et la force du moteur projette la scie en dir...

Страница 9: ...re application Consultez la section Accessoires pour con na tre la lites des lames adapt es pour cet outil Utilisez toujours des lames bien aff t es Les lames mouss es tendent surcharger l outil et ac...

Страница 10: ...availler 3 Laisser l outil reposer pendant au moins deux minutes 4 R initialiser le limiteur de surcharge en enfon ant le bouton Nota Si l outil ne se met pas en marche apr s avoir appuy sur l interru...

Страница 11: ...Pour r duire le risque de d charge lectrique v rifier avant de chantourner si l aire de travail n est pas travers e par des tuyaux et des fils dis simul s 1 En partant d un coin alignez la ligne de v...

Страница 12: ...LALOI LADUR E DE CES GARANTIES IMPLICITES EST LIMIT E LA P RIODE APPLICABLE DE LA GARANTIE EXPRESSE TEL QUE D CRIT PR C DEMMENT CERTAINS TATS ET PROVINCES NE PERMETTANT PAS DE LIMITATION DE DUR E DES...

Страница 13: ...borde recto Esto mejora la precisi n del corte y reduce la probabilidad de que la hoja se amarre Siempreusehojasdeltama oyformacorrectos diamantevs redonda paralosorificiosdeleje Las hojas que no cor...

Страница 14: ...a a tierra tienen un cable de tres hilo y enchufes de conexi n de puesta a tierra de tres clavijas El enchufe debe conectarse a un tomacorriente debidamente conectado a tierra v ase la Figura A Si la...

Страница 15: ...teral Desenchufe la herramienta antes de cambiar accesorios o realizar ajustes C mo ajustar la profundidad de corte 1 Desconecte la herramienta antes de ajustar la profundidad de la cuchilla 2 Para aj...

Страница 16: ...al cortar metales duros tales como acero inoxidable Para evitar que el pro tector contra sobrecargas apague la herramienta siempre haga uso de una cuchilla afilada y siga las instrucciones de corte in...

Страница 17: ...ara evitar riesgo CENTRO DE SERVICIO Y ATENCI N A CLIENTES Av Presidente Mazarik 29 Piso 7 11570 Chapultepec Morales Miguel Hidalgo Distrito Federal Mexico Tel 52 55 4160 3547 IMPORTADO Y COMERCIALIZA...

Страница 18: ...ENCION A CLIENTES Av Presidente Masarik 29 Piso 7 CP 11570 Col Chapultepec Morales Del Miguel Hidalgo Distrito Federal M xico 01 800 8321949 Lunes a Viernes 9am a 6pm O cont ctanos en www milwaukeetoo...

Отзывы: