4
5
FUNCTIONAL DESCRIPTION
1. Light indicators:
1
2
6
7
3
4
5
Off
--
Port is ready
Red
Continuous
Charging
Red
Flashing Battery pack is too hot or too cold (Charging will begin
when battery reaches correct charging temperature)
Green
Continuous Charging is complete
Red and Green Flashing Damaged or faulty battery pack
2. Label
3. Electrical contacts
4. Battery pack bay
5. Vents
6. Cord
wrap
7. Cord
(with pass-through plug)
6
6
Multi-Bay, Multi-Voltage, Multi-Chemistry
The independent bays on the Multi-Bay
Charger allow for charging up to 3 batteries
at the same time. The batteries can be dif-
ferent voltages (12 to 28 Volts) and different
chemistries (NiCd or Li-Ion). For example,
charge your 12 Volt NiCd battery, 18 Volt
NiCd battery, and 28 Volt Li-Ion battery all
at once.
Cord Wrap/Pass-Through Plug
A convenient cord wrap stores the 9-foot
cord. A pass-through plug keeps an outlet
available for other uses.
Job Site Built
The rugged housing of the Multi-Bay Charger
is well suited for the harsh environment of
job sites. Roll bars and blow-molded plastic
protect the charger during falls and bumps.
The high visibility bright indicator lights are
mounted on top of the charger for 360°
viewing.
Dust covers on the electrical contacts help
keep the dust and debris of job sites out of
the charger. When a battery pack is inserted,
the dust covers automatically retract to allow
charging.
Battery packs can be stored on the bays and
carried on the charger from job to job. When
the charger is plugged in, charging begins for
the packs on the bays.
TOOL USE AND FEATURES
Specifi cations
Catalog No.
48-59-0280 *
Input
Volts AC
120
Input
Amps
6.3
Output
Volts DC
12-28
Output
Amps
3.5
* Charges
MILWAUKEE
18-28V Lithium-Ion battery packs and
MILWAUKEE
12-18V NiCd battery packs.
Symbology
Volts Direct
Current
Volts Alternating
Current
Amps
Hertz
Underwriters
Laboratories, Inc.,
United States and Canada
Double Insulated