Страница 3: ...warm up for one half hour after being turned on Allow an additional l5 minutes for stabilization when you turn a lamp on or off Allow an additiooal 5 minutes for stabilization when switching the LAMP...

Страница 4: ...eys only when the spectrophotometer is used in con junction with an APPLIPAK cartridge and the Accessory Control Module or certain diagnostics tffit corotr 6 Ftr r Tilm f j ml Display or set concentra...

Страница 5: ...INCLUDING BUT NOT LIMITED TO WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR OF MERCHANTABILITY OR OTHERWISE and states Milton Roy s entire and exclusive liability and the Customer s exclusive reme...

Страница 6: ...2 Test Parameter Storage MAINTENANCE TROUBLESHOOTING 9 6 1 Performance Evaluation 6 2 Replacement Parts 6 3 Diagnostics 6 4 MaintenanceandTroubleshooting 6 4 1 Troubleshooting Chart 6 4 2 Error Messa...

Страница 7: ...COMPARTMENT 7 Cell Holder Base is removable for installation of acces sory sample holders e g multipurpose cell holder ambi ent flowcell thermoelectric flowcell and automatic cell positioner 8 lOmm pa...

Страница 8: ...on the spectrophotom eter s back panel to determine what voltage 100 I20 220 ot 240 has been set before you plug your SPECTRONIC 501 or 601 in If the voltage shown on the label plate is not the same...

Страница 9: ...ECOND FUNCTION 100 T ZERO A sets transmittance to 100 or absorbance or concentration to zero 3 7 YES a Moves the monochromator up in wavelength b Causes the monochromator to go to a user specified wav...

Страница 10: ...LMP SAV to dis play the status 3 20 SECOND FUNCTION TUNG turns the tung sten lamp on or off 601 only 3 21 SECOND FUNCTION DEUT turns the deu terium lamp on or off for SPECTRONIC 601 only The current l...

Страница 11: ...remes near 195 nm or 999 nm The SPECTRONIC 501 and 601 provide three levels of signal averaging from 0 minimum filtering to 2 maximum filtering To change the SIG AV value a Enter an integral value of...

Страница 12: ...of the lamps is now activated T tungsten D deuterium or B both Another lamp selection option is STANDBY which turns both lamps off temporarily To select the STANDBY feature enter I SECOND FUNCTION DI...

Страница 13: ...hese parameter values using Diagnostic 4 Enter the desired wavelength and press GO TO Set all the parameters to the desired status or value Press 1 then 4 The display will read ENTRY 14 Press SECOND F...

Страница 14: ...Recorder Output Option has been installed When you press 4 SECOND FUNCTION DIAG the message RECORDER SETUP will appear first You may now select any of the setup options below by pressing 0 l or 2 If y...

Страница 15: ...display indicates the relative gain achieved Numbers are dis played in hexadecimal format 0 through 9 and A through E with 0 being the lowest and F the highest lamp intensity See Section 6 6 14 POWER...

Страница 16: ...gsten halogen lamp burned out Replace lamp c Deuterium lamp burned out Replace lamp d Sample compartment windows dirty Clean windows e Lamps not aligned properly Refer to Section 6 5 f Part malfunctio...

Страница 17: ...been set up to run at the correct voltage level If error persists call Milton Roy service MONO ERROR Check maintenance compartment for obvious obstructions or damage Verify that instrument has been se...

Страница 18: ...in Section 6 6 Lamp and Mirror Alignment before using the instrument 6 5 2 Deuterium Lamp SPECTRONIC 601 only Lamp a TLrn off the spectrophotometer and unplug the power cord b Remove the Maintenance...

Страница 19: ...s and lifting up the door at the back edge d Examine the illuminated filter on the filter wheel to deter mine the position of the light Light should be centered on the filter and on the slit as shown...

Страница 20: ...ear panel of the spectrophotometer This connector serves as the serial port for external commu nications c A 25 pin RS 232 C cable which is installed between the serial port and the external electroni...

Страница 21: ...activated and the 501 601 transmits each char acter it receives back to the display of the external device Exception Control characters S Q R T W G C and X are not echoed f FORMAT COMPUTER or PRINTER...

Страница 22: ...to 500 nanometers and 0 029 absorbance A was measured This data is not between the preset high and low limits The Tungsten T lamp is lurned on 9 1 2 Computer Format This format will be used by the in...

Страница 23: ...ON the 50 t 601 wiu not execute keyboard commands but each key closure will generate an ASCII character corresponding to the key pressed see Appendix C DMD Enters the DISPLAY mode All uppercase letter...

Страница 24: ...ng manner IIIIFFFF where IIII Whole integer value contained in the zero register FFFF Fraction integs values contained in the zero register ZERO REGISTER VALUE IIII FFFF 65536 This data is used by the...

Страница 25: ...F n 0 FAC Outputs the current FACTOR value FAC n Sets the FACTOR FLF Empties the data filter FLR n Tirrns the FLASHING R function ON n 1 or OFF n 0 FLI n Turns the FLASHING T function ON n 1 or OFF n...

Страница 26: ...130 INPUT 5 A REM WAIT FOR OK WHEN THE GOTO IS DONE 140 PRINT 5 ZER REM SET ZERO ABSORBANCE 150 INPUT 5 A REM WAIT FOR COMPLETION 160 PRINT 5 HDG REM ASK FOR THE HDG VALUE 170 INPUT 5 H X REM READ IN...

Страница 27: ...LOCK MODE KLK TABLE OF ASCII CHARACTERS PRODUCED BY SPECTRONIC 501 601 KEYSTROKES CHARACTERS WILL ALSO BE PRODUCED FOLLOWING A CTL K KEY 0 9 ASCII CHARACTER 0_9 CLEAR C SEND S SECOND FUNCTION N DOWN...

Страница 28: ...A Light sources Monochromator Detector Wavelength range Wavelength accuracy Wavelength precision Spectral slitwidth Stray radiant energy Photometric accuracy Photometric stability Noise TUngsten Halog...

Страница 29: ...roducts Division MUnchner Strasse 72 8043 Unterfohring WEST GERMANYIIe ephone 089 950 1 51 Milton Roy Analyiical Products Division Jahnstrasse 22 24 6467 Hasselroth 2 WEST GERN ANYfielephone 0 60 55 3...

Страница 30: ...that manufactures SPECTRONIC instruments The onlv th that has chanqed is our name our commitment to never The Milton Roy Company is proud to be the owners of both the internationally known SPECTRONIC...

Страница 31: ...27 7O53 outside New York stzre aoo 65 r9ss Alaska Hawaii and Canada 716 24A423J TELEX 444 1037 FAX 716 248 4014 To purchase parts supplies or accessories foryour Milton Roy instrument contact our Cust...