![Milton Roy MILROYAL B Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/milton-roy/milroyal-b/milroyal-b_instruction-manual_1797333008.webp)
3
Instruction Manual
1.4 SPECIFICATIONS
Control Air Signal
• 3-15 PSI; specify direct or reverse acting
Supply Air Requirements
• 80-100 PSI
Air Consumption
• 0.25-0.4 SCFM
Linearity
• ±5% full scale
Accuracy
• ±1% or better
Loss of Supply Air Action
• Travel to 100%
Loss of Signal Air Action
• Direct acting-travel to 0%
• Reverse acting-travel to 100%
Pump Capacity Variation over
Instrument Pressure Range
• 0-100% (standard)
• Reduced range (optional)
Minimum Pressure Change Required
to Reset Pump Capacity
• 0.25 PSI
Accessories
• Air Control Panel
• Electro-Pneumatic Relay (converts milliamp signal to 3-15 PSI)
SECTION 1 - DESCRIPTION