background image

Air Driven Air Amplifiers, AA-8, AA-15 & AA-30 • OM-15A 

Troubleshooting Guide 

Symptom Cause 

Remedy 

1.  Will not run at low air 

drive pressures (10 - 15 
psi). 

1.  Excess friction of spool o-

rings 568017. 

1.  Necessitates relubrication or 

replacement of spool o-rings. (See 
instruction for removing spool in 
Figure 2, steps 1, 2, 3.) 

2.  Pump will not cycle, or 

slow cycling. 

1.  Leakage of flow and/or pilot 

tubes. 

2.  Indication that one or both 

pilot valves are 
malfunctioning. 

3.  Build-up of residue in 

muffler. 

1.  Replace o-rings on flow pilot tubes. 

 

2.  Remove pilot valves, inspect and 

repair per instructions in maintenance 
section. 

3.  Remove muffler, disassemble and 

clean. 

1.  Small inlet air supply line. 

Restriction not allowing 
drive seals to function 
properly. 

1.  Increase air inlet piping to 1/2”. Test. 

Replace o-rings in the following order 
(test each step): 

a.  No. 568015 o-ring inside hex 

exhaust port fitting. 

b.  Spool o-rings No. 568017. 
c.  Sleeve o-rings No. 568020. (See 

instructions for removing and 
replacing o-rings.) 

2. High pressure piston 

leakage (AA-15, AA-30). 

2.  Shutoff drive air and remove muffler 

and cycling spool

 completely. Apply 

pressure to pump inlet only. If leakage 
flow is audible out of spool cavity, 
replace pump piston parts per 
individual assembly drawing. 

3. High pressure piston 

leakage (AA-8). 

3.  Remove 3/8” O.D. tube at branch of 

inlet tee. Plug branch of tee. Apply 
inlet pressure to tee. If leakage flow is 
audible out of 3/8” tube, replace pump 
piston seal parts per individual 
assembly drawing. 

4. Check valves contaminated 

or damaged. 

4.  Remove, inspect, clean or replace 

check valve parts as necessary. 

3.  “False” or double cycling 

or continuous exhaust 
bleeding. 

4.  Unit will not dead head 

(stall). 

5.  Insufficient pressure at 

pump inlet. 

5.  See catalog for minimum pump inlet 

pressures to maintain efficiency. 

5.  Excessive moisture or 

liquid outside of muffler. 

1.  Air filter full of water. 

1.  Drain air filter. 

 

Содержание Haskel AA-15

Страница 1: ...OM 15A www haskel com Operating and Maintenance Instructions Air Driven Air Amplifiers Models AA 8 AA 15 AA 30 AA 15 AA 30 AA 8 AA 8 AA 15 AA 30...

Страница 2: ...l data in the catalog Compression Ratio vs Efficiency vs Service Life Compression ratio is pump output vs pump inlet pressure psi absolute Note This is completely unrelated to the Area Ratio discussed...

Страница 3: ...se final pressure regulation is best accomplished from a high pressure regulator installed downstream Pumping Speed The pumping speed or cycling speed of the amplifier may be controlled by the speed c...

Страница 4: ...shown in photos 4 thru 6 or an L shaped hook bent from 1 8 diameter brass rod 3 Replace any 568020 o rings or the bumper spacer if damaged worn or swollen 4 Lubricate o rings with light coat of Haske...

Страница 5: ...tem if shank is bent or damaged 4 Replace stem if molded seat is damaged 5 Reassemble in the reverse manner NOTE Unless excessive leakage occurs it is not advisable to replace the o ring seal for the...

Страница 6: ...als are faulty and repair is necessary Check also for external air leaks at plugs or worn 568015 o ring inside exhaust fitting Disassembly and Repair of Air Drive Section and Air Piston 1 Remove 4 tie...

Страница 7: ...15 o ring inside hex exhaust port fitting b Spool o rings No 568017 c Sleeve o rings No 568020 See instructions for removing and replacing o rings 2 High pressure piston leakage AA 15 AA 30 2 Shutoff...

Страница 8: ...OM 15A AA 15 AA 30 AA 8 8 AA 8 AA 15 AA 30 AA 8 8 AA 15 15 AA 30 30 x 2 50 1 12 AA 30 2400 2 200 2 600 800 2 O 2 3 28442...

Страница 9: ...OM 15A AA 15 AA 30 AA 8 9 AA 15 AA 30 AA 8 1 2 NPT 150 2 1 800 2 AA 8 1500 2 AA 15 3000 2 AA 30 28728 30 2 15821 1 1 90 2 3 8 15 30 30 2 4 AA 8 2 x 7 2 5...

Страница 10: ...OM 15A AA 15 AA 30 AA 8 10 2 1 O 568017 O 568015 2 28584 4 6 L 1 8 3 O 568020 4 O 28442 5 6 7 8 2 1 28584 2 3 O 4 5 6...

Страница 11: ...OM 15A AA 15 AA 30 AA 8 11 4 5 6 1 O 2 27375 3 3 4 5 O Tru Arc 4 27375...

Страница 12: ...OM 15A AA 15 AA 30 AA 8 12 1 1 8 17658 2 2 0 160 2 3 O 568017 O 568020 O 568015 1 2 O 3 4 5 6 7 8 9 10 28442 11 16 18...

Страница 13: ...OM 15A AA 15 AA 30 AA 8 13 1 10 15 2 1 O 568017 1 O 2 1 2 3 1 1 O 2 2 2 3 3 1 1 1 2 O O 568015 O 568017 O 568020 O 2 AA 15 AA 30 2 3 AA 8 3 3 8 T T 3 8 4 4 3 4 5 5 5 1 1...

Страница 14: ...AA 8 AA 15 AA 30 OM 15A 14 Haskel AA 8 AA 15 AA 30 AA 8 8 AA 15 15 AA 30 30 50 12 1 AA 30 2400 200 600 800 2 3 P N 28442...

Страница 15: ...AA 8 AA 15 AA 30 OM 15A 15 AA 8 C AA 15 C AA 30 C 1 2 150 1 800 AA 8 1500 AA 15 3000 AA 30 Haskel 28728 30 16821 1 1 90 2 3 8 15 30 30 4 AA 8 x 7 5...

Страница 16: ...AA 8 AA 15 AA 30 OM 15A 16 2 1 568017 568015 2 P N 28584 4 6 L 1 8 3 568020 4 Haskel 28442 5 6 7 8 2 1 28584 2 3 4 5 6...

Страница 17: ...AA 8 AA 15 AA 30 OM 15A 17 4 5 6 1 2 27375 3 3 4 5 Tru Arc 4 27375...

Страница 18: ...AA 8 AA 15 AA 30 OM 15A 18 1 17658 2 1 8 2 0 160 3 568017 568020 568015 1 2 3 4 5 6 7 8 9 10 28442 Haskel 11 16 18...

Страница 19: ...A 15 AA 30 OM 15A 19 1 10 15 1 568017 1 2 1 2 3 2 1 2 3 1 2 3 1 1 1 2 a 568015 b 568017 568020 2 AA 15 AA 30 2 3 A 8 3 3 8 3 8 4 4 Remove inspect clean or replace check valve parts as necessary 3 4 5...

Страница 20: ...for lifting E Safety labels on the machines and meanings are as follows General Danger Read Operator s Manual F In an emergency turn off the air supply G Warning If the pump s were not approved to AT...

Страница 21: ......

Страница 22: ...warranty claim and to expedite the return of replacement to the owner If unit has been disassembled or reassembled in a facility other than Haskel warranty is void if it has been improperly reassemble...

Отзывы: