General installation and maintenance instructions
SCROLL ENCLOSURE AIR COMPRESSOR
Manual n° 5.18396. VERSION 0 – GB
09/2007
Page 16 / 22
Insert tip seal so that the lip of tip seal is on the bottom of seal groove and inner side of involute and the direction of lip
faces the center of involute (curving spiral). See Figure 5. This is to be done for both FS and OS sets.
Use caution not to tear or distort lip.
•
Insert new HP tip seal from the center section for OS or Orbit Scroll so that there will be no clearance at the tip
(start) section (See Figure 5 and 6).
•
Insert so that new LP tip seal will contact closely with HP tip seal inside Scroll Groove.
Insert approximately half of the LP tip seal and remove the tip seal to confirm
that a notch in the tip seal has been created. This will prevent movement
during installation (See Figure 8).
•
Repeat the same procedure for FS or Fixed Scroll tip seal set, remove both the dust seal and backup tube located
on outermost side FS set.
Model Size
Nm
Pulley bolt
M8 19.775
Housing nut (see figure 1)
M10 29.945
Chart 19 – Bolt Nm
•
Insert new backup tube in the FS Scroll in the 6 o’clock position (See Figure 9).
•
Insert new dust seal on the backup tube.
•
After replacing tip seal set, reassemble Fixed Scroll set to the Orbit Scroll. Tighten nuts and bolts temporarily and
confirm if pump pulley rotates smoothly by hand and tighten them firmly. Tightening torques are:
First Second
Bolt Nm
1.921 Nm
29.945 Nm
Note: Assemble so that dust seal and tip seal will not drop between Orbit Scroll set and Fixed Scroll set.