Chapter 2. How to Configure and Program the Control
PELLERIN MILNOR CORPORATION
Figure 31: Flow meter button
8. When
the
Flow Meter Calibration
) appears, wait for the
flow meter count
field to reset to 0.
Figure 32: Flow Meter Calibration screen
9. Touch
the
Water Valve Start
button (
) to open the water valves. Water flows into
the calibration container. The flow meter count value increases as water flows past the flow
meter.
10. When the desired weight or volume of water is in the container, touch the
Water Valve Stop
button. Do not overfill the container!
11. Touch the
Water Quantity
button to open the
Water Quantity
screen (
39
Содержание MilTouch-EX