MSSM0116AE/8809BV
È
SETTING LIMIT SWITCHES
Ê
Limit Switches—Including Microswitches—
Will Be Damaged If Over-actuated!
Any limit switch will be damaged if it bottoms out forcefully. This can bend the rotary shaft or damage
internal components and may cause the switch to stick in one position either permanently or intermittently. Be
aware that an intermittently sticking switch can be mistaken for a malfunctioning microprocessor!
Limit switches must function properly to ensure the safe operation of the machine.
☞
Inspect switches regularly.
☞
Never operate a machine with a malfunctioning limit switch.
Ê
Setting Switches
Ë
Travel of Rotary Lever or Plunger
—Set switch and target so that after the switch contacts close (as de-
termined by an ohmmeter), the lever or plunger will then move approximately half of its additional available travel
(see FIGURE 2).
NOTE: It is impossible to determine by feel, sound, or experience at what point the switch contacts make.
The only reliable method is to use an ohmmeter. Switches may also be bench-tested, and the plunger or
rotary shaft scribed to mark this point.
FIGURE 1a
Rotary Lever Switch
FIGURE 1b
Plunger Switch
FIGURE 1c
180° Roller
Plunger
FIGURE 1d
90° Roller Plunger
Switch
FIGURE 2a
Rotary Lever
FIGURE 2b
Plunger Switches
(Roller Plunger Switch Shown)
Î
FIGURE 1
(MSSM0116AE)
Î
Limit Switch Types
Î
FIGURE 2
(MSSM0116AE)
Î
Where Lever or Plunger Should Stop
B
B
B
Содержание KURSPK0025
Страница 18: ...HURSPK0026 00186 Page 9 of 21 Torque To 25 ft lb 33 9 Nm Main Dome Coupling Figure 2 ...
Страница 19: ...HURSPK0026 00186 Page 10 of 21 Downlock Shims Placed on Bed in order to Shim Main Bell Air Cylinder Figure 3 ...
Страница 20: ...HURSPK0026 00186 Page 11 of 21 One of the Four Main Bell Air Cylinder Bolts Figure 4 ...
Страница 21: ...HURSPK0026 00186 Page 12 of 21 Main Bell Air Cylinder Shims ...
Страница 24: ...HURSPK0026 00186 Page 15 of 21 Figure 7 Right Hand Side Lock Shaft Bearing ...
Страница 25: ...HURSPK0026 00186 Page 16 of 21 Upper Cross Member Shaft Lock Uplock Jaw Figure 8 ...
Страница 27: ...HURSPK0026 00186 Page 18 of 21 Figure 10 Old Setup of Dome Full Up Contact Switch and Bracket Figure 11 ...
Страница 29: ...HURSPK0026 00186 Page 20 of 21 Figure 13 ...
Страница 30: ...HURSPK0026 00186 Page 21 of 21 Figure 14 Lock Ring Bolts Location of Downlock Shims ...