48
Pellerin Milnor Corporation
Scroll to
Program menu
item
0
before exiting
Program mode
.
PROGRAM
0
MENU
This is
Program menu
item
0
. It's now safe to turn the
Run/Pro-
gram keyswitch
to the
Run
position.
OK TURN KEY TO RUN
Returns to
Formula menu
.
RUN FORMULA
Formula menu
; run a formula or shut down the machine.
00
OK TO POWER OFF
2.3.6
Data Transfer (Option 4)
BNCJUP05.C01 0000195299 C.2 D.2 A.6 1/2/20 1:16 PM Released
Certain Milnor
®
controllers described in this manual can transfer memory between the machine
and a Milnor
serial memory storage device
or between two machines. Refer to
lers Capable of Transferring Memory, page 48
to determine the hardware and software require-
ments for memory transfer. See
5.3: Construction of External Serial Link Cables, page 80
inter-machine cable specifications and assembly instructions.
Table 10.
Controllers Capable of Transferring Memory
Machine
Controller
Typical Machine
Models
Controller Software
Later Than
Processor Board Later
Than
E-P Express
®
30015T_X, 30022T_X
WUEPXPRSA/22004
08BH18EPYT REV. K
E-P Express
®
Gear Guardian
®
WUT5XGGA/22GGF
E-P Plus
®
30015V_J, 36026V_J,
42026V_J
WUV7J1B/2200K
08BH18EPDT REV. K
30015H_J, 30022H_J
WUH7J1A/2200E
30022X_J
all versions
CAUTION:
Configuration data will be overwritten. —
When transferring data from
one machine to another, the formulas and configuration data of the
Master
machine will be written to the
Slave
machine. Partial memory transfer is
not possible.
�
Record all configure data from the
Slave
machine before beginning the
download, especially “Offset Height.” Restore this value to the
Slave
ma-
chine after the download is finished.
�
For best results both machines in a machine-to-machine transfer must be identical
models with identical options and controller software, and industry configuration (e.g.,
36026V6J with steam, hot and cold water; software version WUV7J1B/2200K; and con-
figured for Commercial Laundry facilities).
NOTICE:
For data transfer to succeed, the processor boards on all included washer-ex-
tractors must have the Milnor part number specified in
Table 10: Controllers Capable of
with the specified software installed.