80
Pellerin Milnor Corporation
Table 15.
DIP Switch Positions for E-P Plus
®
and E-P Express
®
Machines (External transmit
button required)
Processor Board
Part Number
Processor
Board Revision
Code
Machine Software
and Revision
Storage Device
Software and
Revision
DIP Switch
Setting
30015HxJ and 30022HxJ Models
08BH18EPDT
K
WUH7JA/2200E
WUNTIA/00008
E
VxJ Models
08BH18EPDT
K
WUV7J1B/2200K
WUNTIA/00008
E
30015T5X and 30022T5X Models
08BH18EPYT
K
WUEPXPRSA/22004
WUNTIA/00008
E
All E-P Express Gear Guardian Models
08BH18EPYT
K
WUT5XGGA/22GGF
WUNTIA/00008
E
08BH18EPWT
K
WUMWRXGG/(any)
WUNTIA/00008
E
Key:
A
All switch positions OFF
B
Position 4 ON; all others OFF
C
Position 5 ON; all others OFF
D
Positions 1 and 5 ON; all others OFF
E
Positions 4 and 5 ON; all others OFF
BNCUUP02 / 2018303
BNCUUP02
0000196987
A.9
1/2/20 1:30 PM
Released
5.3
Construction of External Serial Link Cables
BNCUUP02.C01 0000196986 C.2 A.9 1/2/20 1:30 PM Released
This document provides information for on-site fabrication of certain types of serial communica-
tion cables. Programmable data can be transferred between compatible machines or between a
machine and a Milnor
®
serial memory storage device
(see related note below), using the down-
load cables described in
5.3.2.2: Connecting Two or More Machines for Machine-to-machine
and
5.3.2.3: Connecting a Machine to a Serial Memory Storage Device, page
respectively. These cable(s) connect to the cabinet-mounted 9-pin DIN type receptacle shown
in
Figure 14: 9-Pin DIN Connector Pin Identification (from wire entry side of connectors), page
and may be installed temporarily or permanently, as appropriate.
NOTE:
The currently approved printers and printer configuration settings are provided
in
5.4: Printer Requirements and Settings, page 84
. A pre-assembled machine-to-printer
cable similar to the cable described here, is available from Milnor (P/N 10YMK2PNTR).
NOTE:
The Milnor
serial memory storage device
(also known as a
download box
) con-
tains nonvolatile memory to hold a back-up copy of the programming and configuration
data for
one machine
. This data is transferred between the machine and the memory stor-
age device via the DIN receptacle on the machine. Two models are currently available:
KXMIC00507 and KXMIC00508. The already wired cable and DIN connector are in-
cluded as part of the memory storage device. Consult the Milnor Service department to
determine the correct device for a particular application.
Содержание E-P Plus
Страница 2: ......