Pellerin Milnor Corporation
Figure 2.
Incorrect Configurations That Let the Chemical Supply Go In the Machine by Gravity
Schematic Views
Legend
P.
Pump
T.
Chemical tank
D.
Chemical tube. Liquid in the gray areas can go in the machine.
2. Equipment and Procedures That Can Prevent Damage
BNUUUR02.R02 0000160545 A.2 A.8 8/30/17 3:28 PM Released
Use the chemical manifold supplied.
There is a manifold on the machine to attach chemical tubes from a chemical pump system. The
manifold has a source of water to flush the chemical supplies with water.
Prevent Damage from Chemical Supplies and Chemical Systems