Chapter 3. Routine Maintenance
PELLERIN MILNOR CORPORATION
a formula or operate the machine manually. It is not necessary to do the test when the
machine operates.
3. Operate an emergency stop mechanism (examples - button, kick plate, pull cord). If the
mechanism operates correctly, the operator alarm comes on. Did this occur?
Yes
—Release the emergency stop mechanism if necessary. For example, if this is an
emergency stop button, turn the button clockwise to unlock it. Push the start button
(
1
). Do the test on a different emergency stop mechanism. Continue until you do the
test on all emergency stop mechanisms on the machine.
No
—An electrical component is defective. Shut down the machine. Do not let the
machine operate until you correct the problem.
3.1.6.
Maintenance Components—Large Extractors
[Document BIWUUM03]
Figure 20: Grease Ports for Grease-only Bearing Assembly
Grease Plate 01-10025X, 01-10025Y, or 01-10025Z
Legend
.
1.
Seal grease port
2.
Rear bearing grease port
3.
Front bearing grease port
4.
Grease plate part number.
Make sure you use the
grease instructions for the
plate on your machine:
01-10025X, 01-10025Y,
or 01-10025Z.
41
Содержание 48040F7B
Страница 2: ......
Страница 4: ......
Страница 5: ...English 1 1 ...
Страница 6: ......
Страница 8: ...Applicable Milnor products by model number 48040H7N 68036H5N 4 ...
Страница 51: ...Deutsch 2 47 ...
Страница 52: ......
Страница 54: ...Gilt für die Milnor Produkte mit den folgenden Modellnummern 48040H7N 68036H5N 50 ...
Страница 99: ...中国的 3 95 ...
Страница 100: ......
Страница 102: ...适用的 Milnor 产品型号 48040H7N 68036H5N 98 ...
Страница 114: ...2 安全 PELLERIN MILNOR CORPORATION 图 2 使皂液可以通过虹吸管进入机器的错误配置 示意图 标注 P 泵 T 皂液罐 S 虹吸作用在这里发生 皂液罐和皂液管灰色区域的液体可以进入机器 110 ...