Chapter 4. Troubleshooting
PELLERIN MILNOR CORPORATION
The wash program continues. The display shows the error until the operator touches the
Cancel
button.
4.1.1.13.
Inverter Tripped (12)
—
Inverter error:
The inverter that controls the motor had an error.
The machine controller cannot tell about the specific error. See the inverter documentation for
details.
The controller stops the wash program and turns off all outputs. Correct the error condition, touch
the
Cancel
button, then press the
Start
button to resume the wash program.
4.1.1.14.
External Fault Error (13)
—This message is triggered by a device external to the Milnor
machine.
This error usually originates from the chemical supply system. The wash program continues. The
display shows the error until the operator touches the
Cancel
button.
4.1.1.15.
Brake Pressure Fault (14)
—
Brake Pressure:
Low air pressure in the brake release air
cylinder caused by low air pressure, a leaking air cylinder piston cup, leaking/pinched air lines,
leaking quick-release air valves, or a faulty pressure switch or pilot air valve.
If the air pressure in the brake system is less than the required pressure 8 seconds after the
beginning of the step, the controller stops the wash program and turns off all the outputs. Correct
the error condition, touch the
Cancel
button to reset the 8-second timer, then press the
Start
button to resume the wash program.
4.1.1.16.
Bearing Pressure Fault (15)
—
Injecting less than 5 PSI (34.5 kPa):
The machine is
injecting less than 5 PSI (34.5 kPa) behind the excluder seal to protect the bearings. Do a check
of the air supply and the sensor circuit.
If the main bearing pressure is less than the required pressure 8 seconds after the beginning of the
step, the controller stops the wash program and turns off all the outputs. Correct the error
condition, touch the
Cancel
button to reset the 8-second timer, then press the
Start
button to
resume the wash program.
4.1.2.
Messages that Can Occur on MilTouch-EX
™
Models Only
4.1.2.1.
Brake Pads Worn (20)
—The disk brake pads are worn and should be replaced.
4.1.2.2.
Control on Clean Side (21)
—The controls on the discharge side of a Staph Guard
®
model
are enabled.
4.1.2.3.
Check Balance System/Excursion Switch (23)
—The balance system or the excursion
switch tripped.
4.1.3.
Messages that Can Occur on Automatic Load/Discharge
MilTouch-EX
™
Models Only
4.1.3.1.
Brake Pads Worn (16)
—The brake pads used to slow the cylinder after an extract are worn.
Replace the pads.
42
Содержание 30015V8Z
Страница 2: ......
Страница 4: ......
Страница 5: ...English 1 1 ...
Страница 6: ......
Страница 61: ...Deutsch 2 57 ...
Страница 62: ......
Страница 118: ......
Страница 119: ...Français 3 115 ...
Страница 120: ......
Страница 180: ......
Страница 181: ...Nederlands 4 177 ...
Страница 182: ......
Страница 235: ...Ελληνική 5 231 ...
Страница 236: ......
Страница 291: ...Español 6 287 ...
Страница 292: ......