Fall Clearance

from Working Surface 

to Next Lower Level

Self-Retracting Lifeline/Fall Limiter Fall Clearance:

Fall clearance requirements when using a self-retracting 

lifeline (SRL) or fall limiter are taken from the working surface 

to the next lower level.  

Fall clearance calculations are based on the length and 

deflection of the lifeline, a 3-1/2 ft. (1.07m) maximum Miller 

SRL/fall limiter fall arrest distance, and the number of workers 

connected to the system.  The SRL/fall limiter calculations as-

sume the worker is standing upright and is located directly ad-

jacent to the horizontal lifeline with the SRL/fall limiter directly 

overhead and above the level of the harness attachment 

point.  Working away from the point of attachment or crouch-

ing to perform work increases the amount of fall clearance 

required.  All of these factors must be carefully considered to 

ensure that there is adequate fall clearance. 

~IMPORTANT~

Miller Fall Protection

always recommends that

a 3 ft. (.9m) safety factor

be added to all

fall clearance calculations

provided in these tables.

If, in your particular application, there is not adequate 
fall clearance to ensure maximum worker safety, contact 
Miller Technical Services to discuss your options.  Any 
variations to the horizontal lifeline system must be ap-
proved by Miller Fall Protection.

 

**For lifeline spans between the span lengths listed in the fall 
clearance charts, use the next higher lifeline span calcula-
tions.  Example:  For a 70 ft. lifeline, use the 90 ft. fall clearance 
calculations. 

Total Fall Clearance Required*

for One to Two Workers

and Three to Four Workers

when using a

Self-Retracting Lifeline/Fall Limiter

with a Xenon HLL System

  Single-Span Systems

System/

Span 

Length**

[ft (m)]

Single

Shock Absorber System 

for 1-2 Workers

Double

Shock Absorber System 

for 3-4 Workers

10 

(3m)

9’-7” 

(2.92m)

10’-5” 

(3.18m)

15 

(4.5m)

10’-1” 

(3.07m)

11’-1” 

(3.38m)

20 

(6.1m)

10’-6” 

(3.2m)

11’-7½” 

(3.55m)

25 

(7.6m)

10’-11” 

(3.33m)

12’-2” 

(3.71m)

30 

(9.1m)

11’-3½” 

(3.44m)

12’-8” 

(3.86m)

  Multiple-Span Systems (with 30 ft. spans)

System 

Length

[ft (m)]

Single

Shock Absorber System 

for 1-2 Workers

Double

Shock Absorber System 

for 3-4 Workers

30 

(9.1m)

11’-3½” 

(3.44m)

12’-8” 

(3.86m)

60 

(18.2m)

11’-6½” 

(3.52m)

12’-10½” 

(3.93m)

90 

(27.4m)

11’-9” 

(3.58m)

13’-1” 

(3.99m)

120 

(36.5m)

11’-11½” 

(3.65m)

13’-3” 

(4.04m)

150 

(45.7m)

12’-1½” 

(3.7m)

13’-5” 

(4.09m)

180 

(54.8m)

12’-3½” 

(3.75m)

13’-7” 

(4.14m)

210 

(64m)

12’-5” 

(3.79m)

13’-9” 

(4.19m)

240 

(73.1m)

12’-7” 

(3.83m)

13’-11” 

(4.24m)

270 

(82.2m)

12’-8½” 

(3.87m)

14’-½” 

(4.28m)

300 

(91.4m)

12’-10” 

(3.91m)

14’-2” 

(4.32m)

330 

(100.5m)

12’-11½” 

(3.95m)

14’-3½” 

(4.36m)

360 

(109.7m)

13’-1” 

(3.99m)

14’-5” 

(4.4m)

390 

(118.8m)

13’-2” 

(4.01m)

14’-6½” 

(4.43m)

420

(128m)

13’-3½” 

(4.05m)

14’-8” 

(4.47m)

450 

(137.1m)

13’-4½” 

(4.08m)

14’-9” 

(4.5m)

480 

(146.3m)

13’-6” 

(4.12m)

14’-10½” 

(4.54m)

510 

(155.4m)

13’-7” 

(4.14m)

15’ 

(4.57m)

www.netzerotools.com

www.netzerotools.com

Содержание Xenon I283

Страница 1: ...I283 MFP9720152 www netzerotools com www netzerotools com...

Страница 2: ...4 1 Installation of D Bolt Anchor to Beam or Structure 4 2 Installation of Universal Intermediate Brackets 4 3 Installation of Horizontal Lifeline Assembly 4 4 Tensioning Horizontal Lifeline 4 5 Inst...

Страница 3: ...ties unusual wear or deterioration must be immediately discarded Any equipment subject to a fall must be removed from service The user shall have a rescue plan and the means at hand to implement it wh...

Страница 4: ...any hazard which it is not designed to withstand Consult the manufacturer in cases of doubt 2 2 System Warnings and Limitations End and Intermediate System Load Requirements lbf kN for Xenon HLL Syste...

Страница 5: ...g Shock Absorber 5 Cable Clips D Bolt Anchor Shock Absorber D Bolt Anchor Intermediate Support Bracket Thimble Anchor Shackle Swageless Cable Fitting Cable Clips 3 0 Xenon Kit Diagrams and Component D...

Страница 6: ...el swageless cable fitting for 5 16 8mm wire rope XC00030 Cable Lifeline 1 5 16 8mm diameter stainless steel wire rope 30 9 1m length Part no will change depending on length specified Example XC00120...

Страница 7: ...t these procedures to install D bolt anchor on opposite end of lifeline system 4 1 Installation of D Bolt Anchor to Beam or Structure Fig 1d Fig 1c 3 76 2mm 1 5 38 1mm 4 125 104 8mm Working Thickness...

Страница 8: ...position Insert the bolt completely through the aligned holes NOTE The bolt must enter through the side with the star hole Attach the washer and nut 3 Slide the plastic cable guides into position in...

Страница 9: ...k absorber thus exposing the jaw bolt and eyebolt threads Note When fully open the shock absorber will measure ap proximately 22 1 2 572mm from end of jaw to end of eyebolt The shock absorber is desig...

Страница 10: ...o additional cable clips spacing them 3 1 4 83mm apart Torque cable clip nuts to 17 ft lbs 23Nm Procedures D and E apply to the assembly required on the opposite lifeline end Note For multiple span sy...

Страница 11: ...nd the potential fall forces which may be imposed upon the worker and the system 4 4 Tensioning Horizontal Lifeline 1 To prevent the lifeline from twisting while tensioning use an open end wrench to h...

Страница 12: ...will be between 1 16 1 6mm and 5 32 4mm maximum without any load being applied 5 Connect one end of the shock absorbing lanyard or self retracting lifeline fall limiter to the back D ring of the harn...

Страница 13: ...iller Fall Protection always recommends that a 3 ft 9m safety factor be added to all fall clearance calculations provided in these tables If in your particular application there is not adequate fall c...

Страница 14: ...iations to the horizontal lifeline system must be ap proved by Miller Fall Protection For lifeline spans between the span lengths listed in the fall clearance charts use the next higher lifeline span...

Страница 15: ...nctioning or missing components Check cable tension per section 4 4 Tensioning Horizontal Lifeline Inspect shock absorber to ensure that the red label STOP fall indicator is not exposed Inspect Xenon...

Страница 16: ...r Approved by Approuv par Aprobado por Approved by Approuv par Aprobado por Approved by Approuv par Aprobado por Approved by Approuv par Aprobado por Approved by Approuv par Aprobado por DATE OF MANUF...

Страница 17: ...tes Les produits de protection contre les chutes Miller sont soumis des essais pour v rifier qu ils r sistent une usure normale ils ne sont cependant pas indestructibles et peuvent s endommager en cas...

Страница 18: ...www netzerotools com www netzerotools com...

Страница 19: ...rotection Miller X00300 Xenon Permanent Horizontal Life Line Kit Fall Protection Miller X00330 Xenon Permanent Horizontal Life Line Kit Fall Protection Miller X00360 Xenon Permanent Horizontal Life Li...

Отзывы: