background image

7

U s e r   I n s t r u c t i o n s   -   E n g l i s h

4.2 Vi-Go MANUAL PASS-

THROUGH System

1)  Top Bracket Assembly

 

with Inline Shock Absorber

• Inline shock absorber reduces the forces imposed on 

the system and structure in the event of a fall.

• 

May be installed to extend above the ladder to allow 

workers to step safely onto the platform without dis-
connecting from the lifeline for maximum protection.

• Also available with a 7 ft. (2m) or 10 ft. (3m) top 

bracket.

6)  Bottom Bracket Assembly

 

with Lifeline Tensioner

• Dual function lifeline tensioner indicates when the 

lifeline is properly adjusted and prevents ladder rung 
deformation.

4)  Manual Pass-Through Cable Guide

• Holds the cable in position, securing it away from the 

ladder or structure. 

• Fully convertible to accommodate low and high wind 

conditions.

• Manual pass-through feature requires cable to be 

released from the clamping position before the cable 
sleeve can pass by it.

5)  Vi-Go Manual Pass-Through

 

Cable Sleeve

• 

Cable sleeve purchased separately.  Available 

with integral swivel and auto-locking carabiner, 
with the carabiner only, or without a connector.

• Easily attaches to the cable and offers hands-

free trailing operation between intermediate cable 
guides.

• Locks instantly in the event of a fall.

3)  Cable Lifeline

• 3/8” galvanized steel cable lifeline.

3

4

5

6

1

2

2)  Quick Link

• Provides a quick and easy connection of the lifeline 

to the inline shock absorber.

actoolsupply.com

actoolsupply.com

Содержание Vi-Go

Страница 1: ...actoolsupply com actoolsupply com actoolsupply com...

Страница 2: ...r Climbing Safety System Miller Honeywell VG 130FT Vi Go Ladder Climbing Safety System Miller Honeywell VG 140FT Vi Go Ladder Climbing Safety System Miller TRS 50FT Vi Go Ladder Climbing Safety System...

Страница 3: ...arts 5 0 System Installation 8 14 5 1 Installation of Top Bracket Assembly 5 2 Installation of Cable to Top Bracket Assembly 5 3 Installation of Intermediate Cable Guides 5 4 Installation of Bottom Br...

Страница 4: ...d persons users must reference the regulations governing occupational safety as well as applicable standards i e ANSI or CSA Refer to product labeling for information on specific OSHA regulations and...

Страница 5: ...not strike a user below Note According to ANSI A14 3 only one worker may be on the system between cable guides Fall Clearance Ensure that adequate clearance exists in the fall path to avoid striking...

Страница 6: ...mber of users on the system and installation to the structure i e number of rung clamp assemblies used For calculation purposes in determining the load each ladder rung must be able to withstand assum...

Страница 7: ...stallation of the cable sleeve to the cable Hands free trailing while climbing and descending Spring activated mechanisms always move device back to initial position Dual locking mechanism prevents ac...

Страница 8: ...l Pass Through Cable Guide Holds the cable in position securing it away from the ladder or structure Fully convertible to accommodate low and high wind conditions Manual pass through feature requires...

Страница 9: ...d two M10 1 5mm locknuts TRCG Manual Pass Through Cable Guide Galvanized steel cable bracket with convertible polyurethane cable retainer head includes 3 8 16 x 1 1 4 x 2 U Bolt two 3 8 lockwashers tw...

Страница 10: ...users An extra rung clamp assembly may be used in the installation of the top bracket to lower the loads transmitted to each ladder rung see Fig 1c For systems limited to one 1 user the 5 ft 1 5m top...

Страница 11: ...that it will not back out DO NOT USE SYSTEM IF COTTER PIN IS MISSING 5 3 Installation of Intermediate Cable Guides Intermediate Cable Guides are designed to keep the climber from excessively deflecti...

Страница 12: ...adder rung see Fig 4a 2 Install U bolt around underside of ladder rung and through holes provided in cable guide 3 Install washers and torque fasteners to 20 plus or minus 2 ft lbs 5 4 Installation of...

Страница 13: ...e is achieved install jam nut against tensioning nut 6 Discard excess cable by cutting below the lower saddle clip leaving approximately 3 of cable below the lower saddle clip 3 is recommended a minim...

Страница 14: ...le lengths These options are compatible with 3 8 diameter approved cable only 1 Feed cable around cable thimble turning back 5 1 4 of cable from thimble end Install first cable clip one clip base widt...

Страница 15: ...3 Attach the cable sleeve to the front attachment point designated for ladder climbing of the full body harness using a Miller approved auto locking carabiner or other Miller approved connector 4 Veri...

Страница 16: ...ly inspect before each use Regular inspection by a competent person for wear damage or corrosion should be a part of your safety program Replace equipment if any of the defective conditions explained...

Страница 17: ...o por Approved by Approuv par Aprobado por Approved by Approuv par Aprobado por Approved by Approuv par Aprobado por Approved by Approuv par Aprobado por Approved by Approuv par Aprobado por DATE OF M...

Страница 18: ...geantes Les produits de protection contre les chutes Miller sont soumis des essais pour v rifier qu ils r sistent une usure normale ils ne sont cependant pas indestructibles et peuvent s endommager en...

Страница 19: ...actoolsupply com actoolsupply com...

Отзывы: