A complete Parts List is available at www.MillerWelds.com
OM-316 Page 13
4-2. Duty Cycle Charts
A. For AC/DC Models
2 Minutes Welding
8 Minutes Resting
086 727 / 099 602-A
Duty Cycle is percentage of 10 minutes
that unit can weld at rated load without
overheating.
NOTICE
−
Exceeding duty cycle can
damage unit and void warranty.
B. For 300/200A Models*
A. For 225/150A Models*
*These models have a 15% duty cycle when used with 50 Hz input power.
2 Minutes Welding
8 Minutes Resting
B. For AC Models
001 836-A
Duty Cycle is percentage of 10 minutes
that unit can weld at rated load without
overheating.
NOTICE
−
Exceeding duty cycle can
damage unit and void warranty.
For 225A Models*