OM-260311 Page 8
SECTION 3
−
SPECIFICATIONS
3-1. Serial Number And Rating Label Location
The serial number and rating information is located on the bottom of the machine. Use the rating labels to determine input power requirements and/or
rated output. CE model rating labels will also display the following symbols: CE, CCC, WEEE, and IEC 60974-1. For future reference, write serial
number in space provided on back cover of this manual.
3-2. Specifications
.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 4-4 and 4-5 for information on con-
necting input power.
.
This equipment will deliver rated output at an ambient air temperature up to 104
F ( 40
C).
Model
Input Power
Single-Phase
AC
Rated
Welding
Output
Welding
Amperage
Range
Max
OCV DC
(Uo)
Amperes Input
At Rated Load
Output,
50/60Hz,
Single-Phase
KVA/KW @
Duty Cycle
Weight
Dimensions
STH 160
230 Volts Stick
100A @ 24
VDC, 100%
Duty Cycle
4
−
150A
70V
20A
4.5/2.8
6.0 Kg
(13.2 lb)
L = 380 mm
W = 145 mm
H = 245 mm
150A @ 26
VDC, 25%
Duty Cycle
30A
7.0/4.8
230 Volts TIG
100A @ 14
VDC, 100%
Duty Cycle
4
−
160A
70V
13A
3.0/2.0
160A @
16.4 VDC,
20% Duty
Cycle
22A
5.1/3.5
STH 160 L
230 Volts Stick
100A @ 24
VDC, 100%
Duty Cycle
4
−
100A
70V
20A
4.5/2.8
6.0 Kg
(13.2 lb)
L = 380 mm
W = 145 mm
H = 245 mm
230 Volts TIG
100A @ 14
VDC, 100%
Duty Cycle
4
−
160A
70V
13A
3.0/2.0
160A @
16.4 VDC,
20% Duty
Cycle
22A
5.1/3.5