OM-269631 Page 44
7-4. Restoring Factory Defaults
Full System
A full factory reset can be accomplished by pressing STICK and FEEDER buttons on the power source simultaneously for more than four seconds. The
display will show “
rSt
” and then go to dashes when the reset is complete.
7-5. Viewing Software Revision
Pressing the EXX10, EXX16/EXX18 and a hidden button about 1 inch below the FEEDER button on the power source simultaneously will display the
Software Revision.
7-6. Power Source Calibration Procedure
Only qualified persons should install, operate, maintain, and repair this unit.
1.
Calibrated DC voltmeter and clamp-on DC ammeter (e.g. Fluke 337)
2.
Calibration Card
3.
Shorting cable (2/0)
1.
Disconnect cables from all output studs.
2.
Turn on power to the welding system.
3.
Insert Calibration card.
a.
Lift and hold memory card access cover open.
b.
Insert memory card into slot (push card all the way into slot and then release).
c.
Close memory card access cover.
d.
Power source will display CAL.
4.
Calibrate voltage as follows:
a.
Connect voltmeter from + stud to
−
stud.
b.
Press FEEDER button on the power source front panel. Open circuit voltage should now be present from + stud to the
−
stud.
c.
Using the knob on the power source front panel, set the display voltage to the measured value on the voltmeter.
d.
Press FEEDER button on the power source front panel to end the voltage calibration.
e.
Power source will display CAL.
5.
Calibrate amperage as follows:
a.
Connect shorting cable from + stud to
−
stud.
b.
Attach clamp-on ammeter around shorting cable.
c.
Press STICK button on the power source front panel. Amperage should now be flowing in the shorting cable.
d.
Using the knob on the power source front panel, set the display amperage to the measured value on the ammeter.
e.
Press STICK button on the power source front panel to end the amperage calibration.
f.
Power source will display CAL.
g.
Disconnect shorting cable.
6.
Remove Calibration card as follows:
a.
Lift and hold memory card access cover open.
b.
Push in and release memory card to eject card.
c.
Grasp memory card and remove from slot.
d.
Close memory card access cover.
7.
Turn off power to the welding system.