OM-4430 Page 27
Ref. 216 172
−
B
7-2. Variable Frequency (Hz) Generator Power Receptacle RC3
Do not operate equipment re-
quiring a constant frequency
from variable frequency re-
ceptacle RC3.
1
120 V 20 A Variable Frequency
AC Receptacle RC3
Receptacle supplies single-phase
power continuously. Frequency (Hz)
of generator power output changes
with engine speed. Total output avail-
able is 2.4 kVA/kW.
2
Circuit Breaker CB3
CB3 protects receptacle RC3 and
115 volt ac output to Remote Recep-
tacle RC4 from overload. If CB3
opens, the receptacle does not work
and 115 volt ac output at RC4 stops.
Press button to reset circuit
breaker. If breaker continues to
open, contact a Factory Autho-
rized Service Agent.