OM-2232 Page 22
5-3. Removing Right Side Panel and Measuring Input Capacitor Voltage In 230/460 Volt
Models
Turn Off welding power source, and
disconnect input power.
1
Right Side Panel
To remove panel, remove screws
securing panel to unit.
2
Relinking Board PC6
3
Voltmeter
Measure the dc voltage across the
screw terminals on PC6 as shown
until voltage drops to near 0 (zero)
volts.
Proceed with job inside unit. Rein-
stall right side panel when finished.
Tools Needed:
5/16 in
ST-801 718 / ST-801 536-B
1
Y
Significant DC voltage can remain on capacitors af-
ter unit is Off. Always check the voltage as shown
to be sure the input capacitors have discharged be-
fore working on unit.
2
2
3
3
230 VAC input:
+ lead to lower
terminal,
−
lead to
upper terminal
460 VAC input:
+ lead to lower right
terminal,
−
lead to
upper left terminal