4-16. Placing Jumper Links
Ref. 800 103-A
!
Disconnect and lockout/tag-
out input power before
installing or moving jumper
links.
Check input voltage available at
site.
1
Jumper Link Label
Check label
−
only one is on unit.
2
Jumper Links
Move jumper links to match input
voltage.
Close and secure access door, or
go on to Section 4-17.
Tools Needed:
2
1
Do not overtighten
jumper link nuts.
230 VOLTS
Ref. S-174 973-B
575 VOLTS
460 VOLTS
380 VOLTS
400 VOLTS
440 VOLTS
Ref. S-174 975-B
220 VOLTS
(FACTORY OPTION)
200 VOLTS
Ref. S-174 976-B
230 VOLTS
460 VOLTS
3/8 in.