OM-239026 Page 20
7-2. Overload Protection
246152-C
!
Turn off unit and disconnect
input power cord.
1
Fuse F1 (See Parts List For
Rating)
F1 protects the electrical compon-
ents of the filter cleaning system from
overload. If F1 opens the filter clean-
ing system does not operate. Re-
place F1 if open.
To access F1, loosen clamp on lower
flex duct and raise flex duct. Reinstall
flex duct after checking fuse.
2
Circuit Breaker CB1
CB1 protects the blower motor from
overload. If CB1 opens the blower
motor will not run.
To access CB1, reach under front
panel.
To reset CB1, reach under front pan-
el and place CB1 in the On (up) posi-
tion.
If a fuse or circuit breaker opens,
it usually indicates a more seri-
ous problem exists. Contact a
Factory Authorized Service
Agent.