OM-239026 Page 14
SECTION 5
−
INSTALLATION
5-1. Serial Number And Rating Label Location
The serial number and rating information is located on the front of the unit. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.
!
Only qualified persons should in-
stall, operate, maintain, and re-
pair this unit.
!
Installation must meet all Nation-
al, State, and Local Codes
−
have
only qualified persons make this
installation.
!
Do not move or operate unit
where it could tip.
!
Do not use this equipment to sup-
port personnel, large tools, or
other material.
!
Special installation may be re-
quired where gasoline or volatile
liquids are present
−
see NEC Ar-
ticle 511 or CEC Section 20.
Moving The Equipment
1
Lifting Forks
2
Locking Casters
Use wheels or lifting forks to move unit.
If using lifting forks, extend forks beyond
opposite side of unit.
Compressed Air And Power Supplies
3
Compressed Air Supply
(80
−
100 psi/552
−
689 kPa)
Clean, dry, oil-free compressed air is
needed for the cleaning function to oper-
ate properly.
4
115 Volt,
20
Amp AC Grounded
Receptacle
A 115 volt AC,
20
amp individual branch
circuit protected by time delay (type D)
fuses or circuit breaker is required.
Position unit near the welding operation
and close to compressed air supply and
115 volt AC receptacle. Keep unit away
from obstructions that may restrict
movement of the fume collector or ex-
tension arm.
LocFiltair_Mobile1 2018-08
−
800402-A / 245611
5-2. Selecting A Location
2
4
1
3
18 in.
(460 mm)