TM-357 Page 21
Dynasty DX
Trouble
Remedy
Check for proper input and output connections.
Replace electrode.
Check resistance and connections of remote amperage control potentiometer, and replace if
necessary.
Check input and output voltages of hall device HD1 (see Section 6-2). Replace HD1 if necessary.
Check control board PC1 and connections, and replace if necessary (see Section 6-4).
Prior to Serial No. KJ037293, no 24
volts ac output at Remote 14 recep-
tacle RC1.
Reset circuit breaker CB2 if necessary (see Section 7-3).
Check receptacle wiring and connections.
No 115 volts ac output at optional du-
Reset circuit breaker CB1 if necessary (see Section 2-7).
plex receptacle.
Check receptacle(s) wiring and connections.
Fan motor does not run after approxi-
Check and clear blocked fan blade
mately four minutes of operation at
rated load.
Check thermistors RT1 and RT2 on display board PC3 (see Section 6-6).
Check fan motor FM, and replace if necessary.
Wandering arc; poor control of arc
Use proper size tungsten.
direction.
Use properly prepared tungsten.
Reduce gas flow rate.
Tungsten electrode oxidizing and not
Shield weld zone from drafts.
remaining bright after conclusion of
weld.
Increase postflow time.
Check and tighten all gas fittings.
Water in torch. Refer to torch manual.
Содержание DYNASTY DX
Страница 27: ...TM 357 Page 25 Dynasty DX Notes...
Страница 47: ...TM 357 Page 45 Dynasty DX SD 183 036 C...
Страница 49: ...TM 357 Page 47 Dynasty DX SD 189 922...
Страница 51: ...TM 357 Page 49 Dynasty DX SD 183 037 B...
Страница 53: ...TM 357 Page 51 Dynasty DX SD 183 732 A...
Страница 55: ...TM 357 Page 53 Dynasty DX SD 183 732 A...
Страница 57: ...TM 357 Page 55 Dynasty DX SD 183 732 A...
Страница 59: ...TM 357 Page 57 Dynasty DX Notes...
Страница 61: ...TM 357 Page 59 Dynasty DX SD 189 540...
Страница 63: ...TM 357 Page 61 Dynasty DX SD 189 540...
Страница 68: ...TM 357 Page 66 Dynasty DX Notes...