3-1. Included with Your Unit
1
Welding Power Source
2
5 ft (1.5 m) Primary Cord
With Plug
3
Gas Hose
4
Gas Regulator
5
12 ft (3.7 m) Work Cable
With Clamp
6
Air-Cooled 150 Amp TIG
Torch with 12 ft (3.7 m)
Cable
.
Some assembly is required.
For options and accessories see
back of book or contact your dis-
tributor.
.
a Diversion 180 is illustrated
throughout this manual un-
less otherwise indicated.
805 474-A
1
2
3
4
5
6
3-2. Specifications
Diversion 180
Input Power
Welding Amperage
Range
Rated Output
Amps Input At
Rated Output
KVA
KW
Max. OCV
115 VAC
10
−
125
60 A at 12.4 V, 100% Duty Cycle
11.3 (.88)*
1.3 - (.1)*
1.2 - (.03)*
80 VDC
125 A at 15 V, 35% Duty Cycle
26.5 (.88)*
3.1 (.1)*
3.0 - (.03)*
230 VAC
10
−
180
60 A at 12.4 V, 100% Duty Cycle
5.6 (.44)*
1.3 (.1)*
1.2 - (.03)*
150 A at 16 V, 20% Duty Cycle
16 (.44)*
3.7 (.1)*
3.6 - (.03)*
180 A at 17.2 V, 10% Duty Cycle
20 (.44)*
4.7 (.1)*
4.6 - (.03)*
* () While idling.
Diversion 165
230 VAC
10
−
165
60 A at 12.4 V, 100% Duty Cycle
8 (.20)*
1.8 (.04)*
1.2 (.02)*
80 VDC
150 A at 16 V, 20% Duty Cycle
23 (.20)*
5.3 (.04)*
3.7 (.02)*
165 A at 16.6 V, 15% Duty Cycle
25.5 (.20)*
5.9 (.04)*
4.2 (.02)*
* () While idling.
3-3. Serial Number And Rating Label Location
The serial number and rating information for the power source is located on the rear of the machine. Use the rating labels to determine input power
requirements and/or rated output. For future reference, write serial number in space provided on back cover of this manual.