OM-231 313 Page 5
10. GMAW Connections
804 845-A
Tools Needed:
5/8 in
!
Do not move or operate unit where
it could tip.
To prevent overheating, make sure cooling
unit is positioned so airflow is not restricted.
NOTICE
−
If welding power source has a
water valve, do not connect hoses to water
valve. Connect hoses as shown.
1
Coolant Out Hose
2
Coolant In Hose
Fittings have 5/8-18 left-hand threads.
Connect hoses with proper fittings as
shown.
3
Coolant Tank Cap
4
115 Volt AC Grounded Receptacle
An individual branch circuit capable of car-
rying 15 amperes and protected by fuses
or circuit breakers is recommended. Rec-
ommended fuse or circuit breaker size is
15 amperes.
Operation:
Fill tank with proper coolant. Use table in
Section 8 to select proper coolant. Maintain
coolant level at approximately 1 in (25 mm)
below top of filler neck. Connect hoses as
shown. Unit turns on when plugged in.
2
1
3
4
Содержание Coolmate 3.5
Страница 3: ...OM 231 313 Page 1 4 Warning Labels ...