OM-257 798 Page 19
5-3. Connecting Weld Output Cables
Ref. 259 119-A / 259 120-A
!
Turn off power before connecting to
weld output tabs or receptacles.
!
Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your
machine.
Ensure all connections are tight.
Tab Connection
.
Do not place anything between weld
cable terminal and output tab. Make
sure that the surfaces of the weld cable
terminal and output tab are clean.
1
Negative (
−
) Tab
2
Positive (+) Tab
3
Correct Weld Cable Connection For
Single Feeder
4
Correct Weld Cable Connection For
2/0 And Larger Double Cables
5
Incorrect Weld Cable Connection
6
Weld Output Terminal Bolt
7
Nut
8
Weld Cable Terminal
9
Output Terminal
Remove supplied nut and bolt from weld
output terminal. Insert bolt through hole in
weld cable terminal and hole in weld output
terminal. Screw nut onto bolt until weld
cable terminal is tight against output termi-
nal.
Tools Needed:
6
3
7
8
9
5
3/4 in. (19 mm) for output
terminal type connection
6
4
7
8
9
8
2/0 and larger double cables
2
Front View
Rear View
1
Содержание Continuum 350
Страница 17: ...OM 257 798 Page 13 Notes...
Страница 27: ...OM 257 798 Page 23 Notes...
Страница 45: ...OM 257 798 Page 41 Notes...
Страница 47: ...OM 257 798 Page 43 264 238 B...
Страница 48: ...OM 257 798 Page 44 Figure 10 2 Circuit Diagram For Continuum 350 Model Page 2 of 2...
Страница 49: ...OM 257 798 Page 45 264 238 B...
Страница 50: ...OM 257 798 Page 46 Figure 10 3 Circuit Diagram For Contiuum 500 Model Page 1 of 2...
Страница 51: ...OM 257 798 Page 47 265 841 B...
Страница 52: ...OM 257 798 Page 48 Figure 10 4 Circuit Diagram For Continuum 500 Model Page 2 of 2...
Страница 53: ...OM 257 798 Page 49 265 841 B...
Страница 62: ...OM 257 798 Page 58 Notes...