8-3. Checking Generator Brushes
GenBrush2 2012-05 / Ref 205 725
!
Stop engine and let cool.
1
Generator Brush Assembly
Mark and disconnect leads at brush hold-
er assembly. Remove assembly. Press
on brush to be sure springs compress.
Replace assembly if brushes are dam-
aged or if brush material is at or near mini-
mum length. Check length from brush-
holder surface.
1
Minimum Length:
New Length:
Replace Assembly if
Brushes are Damaged
1/4 in. (6.5mm)
5/8 in. (16mm)
8-4. Servicing Air Cleaner
!
Stop engine.
NOTICE
−
Do not run engine without air
cleaner or with dirty element. Engine dam-
age caused by using a damaged element
is not covered by the warranty.
The air cleaner primary element can
be cleaned but the dirt holding capacity
of the filter is reduced with each clean-
ing. The chance of dirt reaching the
clean side of the filter while cleaning
and the possibility of filter damage
makes cleaning a risk. Consider the
risk of unwarrantable equipment dam-
age when determining whether to
clean or replace the primary element.
If you decide to clean the primary ele-
ment, we strongly recommend instal-
ling an optional safety element to pro-
vide additional engine protection.
Nev-
er clean a safety element.
Replace
the safety element after servicing the
primary element three times.
Clean or replace primary element if dirty
(see note above before cleaning).
Replace
primary element if damaged. Replace pri-
mary element yearly or after six cleanings.
1
Housing
2
Safety Element (Optional)
3
Primary Element
4
Dust Cap
5
Dust Ejector
To clean air filter:
Wipe off cap and housing. Remove cap
and dump out dust. Remove element(s).
Wipe dust from inside cap and housing
with damp cloth. Reinstall safety element
(if present). Reinstall cap.
NOTICE
−
Do not clean housing with air
hose.
Clean primary element with compressed
air only.
Air pressure must not exceed 100 psi (690
kPa). Use 1/8 in. (3 mm) nozzle and keep
nozzle at least 2 in. (51 mm) from inside of
element. Replace primary element if it has
holes or damaged gaskets.
Reinstall primary element and cap (dust
ejector down).
Blow
Inspect
4
1
3
5
Keep nozzle 2 in.
(51 mm)
from element.
2
aircleaner1 2/01
−
ST-153 929-B / ST-153 585 / Ref. S-0698-B / Ref. 226 386-B
Optional
Содержание Big Blue 300 PRO Series
Страница 33: ... Complete Parts List is available at www MillerWelds com OM 259 355 Page 29 Notes ...
Страница 40: ... Complete Parts List is available at www MillerWelds com OM 259 355 Page 36 6 7 Fuel Hour Gauge Descriptions ...
Страница 51: ... Complete Parts List is available at www MillerWelds com OM 259 355 Page 47 Notes ...
Страница 59: ...OM 259 355 Page 55 240 670 C ...
Страница 60: ...OM 259 355 Page 56 Figure 10 2 Circuit Diagram For Welding Generator With Kubota Engine ...
Страница 61: ...OM 259 355 Page 57 253 845 B ...
Страница 62: ...OM 259 355 Page 58 Figure 10 3 Circuit Diagram For Welding Generator With Mitsubishi Engine ...
Страница 63: ...OM 259 355 Page 59 250 149 B ...
Страница 74: ...OM 259 355 Page 70 Notes ...