OM-273473 Page 29
C. Best Setup
250 515-B
1
Welding Power Source
2
Electrode Cable
3
Feeder Cable
4
Work Cable
5
Voltage Sensing Lead
6
Robot
7
Workpiece
This arrangement is the best setup for
proper voltage sensing at the workpiece.
Voltage feedback to the welding power
sources will more accurate and result in
reliable arc starts and better arc quality.
Current Flow Path
1
2
3
6
3
2
1
6
4
7
5
5
4
.
Appearance of actual unit may differ from that shown.