OM-273473 Page 23
Input5 2013−04
!
Installation must meet all National and
Local Codes − have only qualified per-
sons make this installation.
!
Disconnect and lockout/tagout input
power before connecting input
conductors from unit. Follow estab-
lished procedures regarding the in-
stallation and removal of lockout/
tagout devices.
!
Make input power connections to the
welding power source first.
!
Always connect green or green/yellow
conductor to supply grounding
terminal first, and never to a line
terminal.
NOTICE − The Auto-Line circuitry in this unit
automatically adapts the power source to the
primary voltage being applied. Check input
voltage available at site. This unit can be con-
nected to any 3-phase input power between
230 and 575 VAC without removing cover to
relink the power source.
See rating label on unit and check input volt-
age available at site.
1
Input Power Conductors (Customer
Supplied Cord)
Select size and length of conductors using
Section 5-10. Conductors must comply with
national, state, and local electrical codes. If
applicable, use lugs of proper amperage
capacity and correct hole size.
Welding Power Source Input Power
Connections
2
Strain Relief Kit 274 563 Supplied With
Machine
Install strain relief of proper size for unit and
input conductors. Route conductors (cord)
through strain relief. Tighten strain relief.
3
Welding Power Source Grounding
Terminal
4
Green Or Green/Yellow Grounding
Conductor
Route green or green/yellow grounding con-
ductor through current transducer and con-
nect to welding power source grounding
terminal first..
5
Welding Power Source Line Terminals
6
Input Conductors L1, L2, L3
Connect input conductors L1, L2, and L3 to
welding power source line terminals.
Reinstall top cover on welding power source.
Disconnect Device Input Power
Connections
7
Disconnect Device (switch shown in the
OFF position)
8
Disconnect Device Grounding Terminal
9
Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding ter-
minal first.
Connect input conductors L1, L2, and L3 to
disconnect device line terminals.
10 Over-Current Protection
Select type and size of over-current protec-
tion using Section 5-10 (fused disconnect
switch shown).
Close and secure door on disconnect device.
Follow established lockout/tagout procedures
to put unit in service.
5-11. Connecting 3-Phase Input Power (Continued)
Notes
Work like a Pro!
Pros weld and cut
safely. Read the
safety rules at
the beginning
of this manual.
Содержание Auto-Continuum 350
Страница 42: ...OM 273473 Page 38 7 2 User Interface Ref 266 061 B 2 1 5 6 7 8 4 16 9 10 11 3 20 12 13 14 15 17 19 18...
Страница 55: ...OM 273473 Page 51 273 905 B...
Страница 56: ...OM 273473 Page 52 Figure 10 2 Circuit Diagram For Auto Continuum 350 Model Page 2 of 2...
Страница 57: ...OM 273473 Page 53 273 905 B...
Страница 58: ...OM 273473 Page 54 Figure 10 3 Circuit Diagram For Auto Contiuum 500 Model Page 1 of 2...
Страница 59: ...OM 273473 Page 55 273 490 B...
Страница 60: ...OM 273473 Page 56 Figure 10 4 Circuit Diagram For Auto Continuum 500 Model Page 2 of 2...
Страница 61: ...OM 273473 Page 57 273 490 B...
Страница 67: ...OM 273473 Page 63 Notes...
Страница 72: ...Notes...
Страница 73: ...Notes...
Страница 74: ...Notes...