OM-194 415 Page 4
2-3.
Typical Connections
Typical Stick (SMAW) Connections
2-4.
Weld Output Terminals And Selecting Cable Sizes
Total Cable (Copper) Length In Weld Circuit Not Exceeding
100 ft (30 m) Or Less
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Turn Off power before
connecting to weld output
receptacles.
Welding
Amperes
10 – 60%
Duty
Cycle
60 – 100%
Duty Cycle
10 – 100% Duty Cycle
100
20
20
20
25
35
50
50
50
150
25
25
35
50
50
70
90
90
200
25
35
50
50
70
90
90
90
Ground
Electrode
250
35
35
50
70
90
90
120
120
Weld cable size (mm
2
) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
Ref. S-0007-D
2-5.
Electrical Service Guide
Model
AC 150 Stick
AC 200 Stick
Input Voltage
230
400
230
400
Input Amperes At Rated Output
28
16
37
22
Max Recommended Standard Fuse Or Circuit Breaker Rating In
Amperes
30
20
40
25
Reference: 1997 National Electrical Code (NEC)
S-0092-J