Complete Parts List available at www.MillerWelds.com
OM-4421 Page 53
Trouble
Remedy
No remote fine amperage control.
Repair or replace remote control device.
Have Factory Authorized Service Agent check OCV control circuit.
B. Welding
−
CC/CV Models
Trouble
Remedy
No weld output; generator power output
okay at ac receptacles.
Place Process/Contactor switch in a Weld Terminals Always On position, or place switch in a Remote
On/Off Switch Required position and connect remote contactor to optional Remote 14 receptacle RC14
(see Sections 5-10 and 7-1).
Check position of Ampere Range switch.
Check position of optional Polarity switch or Polarity/AC switch.
Reset supplementary protector CB11 (see Section 9-9).
Reset supplementary protector CB5 (see Section 9-9). Check for faulty remote device connected to
RC14.
Check and secure connections to Remote 14 receptacle RC14 (see Section 5-10).
Have Factory Authorized Service Agent check connector board PC6 and connections.
Check fuse F2, and replace if open (see Section 9-9). Have Factory Authorized Service Agent check
brushes and slip rings, weld excitation circuit, field current regulator board PC1, and the rotor.
No weld output or generator power out-
put at ac receptacles.
Disconnect equipment from generator power receptacles during start-up.
Check fuses F1 and F2, and replace if open (see Section 9-9). Have Factory Authorized Service Agent
check integrated rectifier SR1, capacitor C9, field current regulator board PC1, and the rotor.
Have Factory Authorized Service Agent check brushes and slip rings, and field excitation circuit.
Erratic weld output.
Check and tighten connections inside and outside unit.
Be sure connection to work piece is clean and tight.
Use dry, properly stored electrodes.
Remove excessive coils from weld cables.
Have Factory Authorized Service Agent check brushes and slip rings.
High weld output.
Check position of Ampere Range switch and Voltage/Amperage Adjust control.
Check engine speed, and have engine manufacturer’s factory authorized service agent adjust if nec-
essary. See Section 9-7 for idle speed adjustment.
Have Factory Authorized Service Agent check field current regulator board PC1, and PC1 voltage feed-
back circuit.
Voltage/Amperage control does not
work when welding in Stick mode.
Place Ampere Range switch in lower range. Voltage/Amperage control does not work with Ampere
Range switch in highest range.
Low weld output.
Check position of Ampere Range switch and Voltage/Amperage Adjust control.
Check engine speed, and have engine manufacturer’s factory authorized service agent adjust if neces-
sary. See Section 9-7 for idle speed adjustment.
Check fuses F1 and F2, and replace if open (see Section 9-9). Have Factory Authorized Service Agent
check integrated rectifier SR1, capacitor C9, field current regulator board PC1, and the rotor.
Electrode sticks to the workpiece more
frequently during low voltage (short arc
length) conditions.
Circuit breaker CB4 may be open. CB4 automatically resets when the fault is corrected (see Section 9-9).
Have Factory Authorized Service Agent check transformer T1 and integrated rectifiers SR4 and SR5.
Low open-circuit voltage.
Check engine speed, and have engine manufacturer’s factory authorized service agent adjust if neces-
sary. See Section 9-7 for idle speed adjustment.
Check position of Process/Contactor switch.
No remote fine amperage or voltage
control.
Place Voltage/Amperage Adjust switch in Remote position.
Check and secure connections to Remote 14 receptacle RC14 (see Section 5-10).
Содержание 907186
Страница 6: ......
Страница 20: ...OM 4421 Page 14 ...
Страница 63: ... Complete Parts List available at www MillerWelds com OM 4421 Page 57 Notes ...
Страница 64: ...OM 4421 Page 58 SECTION 11 ELECTRICAL DIAGRAMS Figure 11 1 Circuit Diagram For CC Welder Generator ...
Страница 65: ...OM 4421 Page 59 240 152 B ...
Страница 66: ...OM 4421 Page 60 Figure 11 2 Circuit Diagram For CC CV Welder Generator ...
Страница 67: ...OM 4421 Page 61 240 153 B ...
Страница 77: ...OM 4421 Page 71 Notes ...
Страница 78: ...OM 4421 Page 72 Notes ...