Complete Parts List available at www.MillerWelds.com
Complete Parts List available at www.MillerWelds.com
OM-4421 Page 40
SECTION 8
−
OPERATING AUXILIARY EQUIPMENT
8-1. Domestic Auxiliary Power Receptacles
191 624-A
2
!
Use GFCI protection when operat-
ing auxiliary equipment. If unit does
not have GFCI receptacles, use
GFCI-protected extension cord. Do
not use GFCI receptacles to power
life support equipment.
!
Unplug power cord before attempt-
ing to service accessories or tools.
1
120 V 20 A AC GFCI
Receptacle GFCI1
2
240 V 30 A AC Twistlock
Receptacle RC1
Receptacles supply 60 Hz single-phase
power at weld/power speed.
!
Test GFCI monthly. See Section 8-4
for GFCI information and for reset-
ting and testing procedures.
3
Supplementary Protector CB1
4
Supplementary Protector CB2
CB1 protects RC1 and the generator wind-
ing from overload. If CB1 opens, RC1 and
GFCI1 do not work. Place switch in On
position to reset.
CB2 protects GFCI1 from overload. If CB2
opens, GFCI1 does not work. Press button
to reset.
If a supplementary protector continues
to open, contact Factory Authorized
Service Agent.
Generator power is not affected by
weld output.
Maximum output is 2.4 kVA/kW from
GFCI1 and 4 kVA/kW from RC1. Maximum
output from all receptacles is 4 kVA/kW.
EXAMPLE: If 13 A is drawn from RC1, only
7 A is available at GFCI1:
(240 V x 13 A) + (120 V x 7 A) =
4.0 kVA/kW
1
3
4
Содержание 907186
Страница 6: ......
Страница 20: ...OM 4421 Page 14 ...
Страница 63: ... Complete Parts List available at www MillerWelds com OM 4421 Page 57 Notes ...
Страница 64: ...OM 4421 Page 58 SECTION 11 ELECTRICAL DIAGRAMS Figure 11 1 Circuit Diagram For CC Welder Generator ...
Страница 65: ...OM 4421 Page 59 240 152 B ...
Страница 66: ...OM 4421 Page 60 Figure 11 2 Circuit Diagram For CC CV Welder Generator ...
Страница 67: ...OM 4421 Page 61 240 153 B ...
Страница 77: ...OM 4421 Page 71 Notes ...
Страница 78: ...OM 4421 Page 72 Notes ...