OM-224 043 Page 10
3-3. Volt-Ampere Curves
va_curve1 4/95
−
SA-178 652 / SA-178 653
Volt-ampere curves show minimum
and maximum voltage and amper-
age output capabilities of unit.
Curves of other settings fall be-
tween curves shown.
A. CC Mode
B. CV Mode
ARC CONTROL
3-4. Installing Turntable for Wire Feeder on Power Source (Optional)
Y
Turn off welding power
source and disconnect input
power before proceeding.
Remove wire spool.
1
Turntable
2
Screw
Remove the 4 screws and the plas-
tic cap on the power source upper
cover and keep them for future use.
Insert the turntable in the upper hole
and secure with 4 screws. Be sure
screws are tight.
If desired, install the wire feeder on
the turntable using the hole in the
bottom of the feeder.
1
2