background image

OM-2223 Page 11

SECTION 3 

 DEFINITIONS

3-1. Symbol Definitions

A

Amperage

V

Voltage

Hz

Hertz

Direct Current

(DC)

Alternating Current

(AC)

Panel/Local

Line Connection

Three Phase

Output

On

Voltage Input

Off

Submerged Arc

Welding (SAW)

Read Operator’s

Manual

Remote

X

Duty Cycle

Percent

U

0

Rated No-Load

Voltage (Average)

U

1

Rated Supply

Voltage

Circuit Breaker

U

2

Conventional Load

Voltage

I

2

Rated Welding

Current

Protective Earth

(Ground)

I

1max

Rated Maximum

Supply Current

I

1eff

Maximum Effective

Supply Current

3-Phase Power

Source With

AC/DC Output

Temperature

Ventilating And Air

Circulating Fan

Increase

IP

Degree Of

Protection

Air Carbon Arc

Cutting  (CAC-A)

Shielding Metal Arc

Welding (SMAW)

Gas Metal Arc

Welding GMAW)

SECTION 4 

 INSTALLATION

4-1. Specifications

Model

Rated Welding

Output

Amperage/Voltage

Range DC

Max

OCV

DC

Amperes Input at Rated Load

Output, 

60 Hz, Three-Phase

Output

Range DC

OCV DC

230 V

460 V

575 V

KVA

KW

1000 Amp

1000 A @ 44

Volts DC  100%

100 

 1250 A In CC

Mode

66 VDC**

180

5.8*

90

2.9*

72

2.4*

73

3.2*

53

0.5*

1000 Amp

Volts DC, 100%

Duty Cycle

10 

 60 V In CV

Mode

66 VDC**

5.8*

2.9*

2.4*

3.2*

0.5*

*While idling

**Open-circuit voltage is 26 volts dc if unit is equipped with optional low open-circuit voltage.

Содержание SQUAREWAVE 1000

Страница 1: ...Processes Description Multiprocess Welding Arc Welding Power Source OM 2223 190 969AC 2007 11 Dimension 1000 Visit our website at www MillerWelds com File Multiprocess...

Страница 2: ...tinue the tradition They re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929 This Owner s Manual is designed to help you get...

Страница 3: ...F 9 SECTION 3 DEFINITIONS 11 3 1 Symbol Definitions 11 SECTION 4 INSTALLATION 11 4 1 Specifications 11 4 2 Duty Cycle And Overheating 12 4 3 Volt Ampere Curves 13 4 4 Selecting A Location 14 4 5 Dimen...

Страница 4: ......

Страница 5: ...cramped positions such as sitting kneeling or lying or when there is a high risk of unavoid able or accidental contact with the workpiece or ground For these conditions use the following equipment in...

Страница 6: ...they are properly prepared according to AWS F4 1 see Safety Standards D Do not weld where the atmosphere may contain flammable dust gas or liquid vapors such as gasoline D Connect work cable to the wo...

Страница 7: ...ns D Keep all doors panels covers and guards closed and securely in place D Have only qualified persons remove doors panels covers or guards for maintenance as necessary D Reinstall doors panels cover...

Страница 8: ...ork NY 10036 8002 phone 212 642 4900 website www ansi org Standard for Fire Prevention During Welding Cutting and Other Hot Work NFPA Standard 51B from National Fire Protection Association P O Box 910...

Страница 9: ...ource lectrique courant lectrique s av re n cessaire se servir de la fonction de t l commande si l appareil en est quip D D autres consignes de s curit sont n cessaires dans les condi tions suivantes...

Страница 10: ...protection Le soudage effectu sur des conteneurs ferm s tel que des r servoirs tambours ou des conduites peu provoquer leur clatement Des tincelles peuven tre projet es de l arc de soudure La project...

Страница 11: ...pour usage ult rieur D Utiliser les quipements corrects les bonnes proc dures et suffi samment de personnes pour soulever et d placer les bouteilles D Lire et suivre les instructions sur les bouteille...

Страница 12: ...provoquer des interf rences D L nergie lectromagn tique risque de provo quer des interf rences pour l quipement lec tronique sensible tel que les ordinateurs et l quipement command par ordinateur tel...

Страница 13: ...Box 371954 Pittsburgh PA 15250 7954 t l phone 1 866 512 1800 il y a 10 bureaux r gionaux le t l pho ne de la r gion 5 Chicago est 312 353 2220 site Internet www osha gov 2 6 Information EMF Consid ra...

Страница 14: ...OM 2223 Page 10 Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...

Страница 15: ...3 Phase Power Source With AC DC Output Temperature Ventilating And Air Circulating Fan Increase IP Degree Of Protection Air Carbon Arc Cutting CAC A Shielding Metal Arc Welding SMAW Gas Metal Arc Wel...

Страница 16: ...heating If unit overheats thermostat s opens output stops and cooling fan runs Wait fifteen minutes for unit to cool Reduce amperage or duty cycle before welding NOTICE Exceeding duty cycle can damage...

Страница 17: ...lt Ampere Curves Volt ampere curves show mini mum and maximum voltage and amperage output capabilities of unit Curves of other settings fall be tween curves shown va_curve1 4 95 ST 199 986 A ST 190 97...

Страница 18: ...de of unit 3 Rating Label Use rating label to determine input power needs Label located under front access door 4 Line Disconnect Device Locate unit near correct input pow er supply Special installati...

Страница 19: ...30 in 762 mm Including lift eye B 23 in 584 mm B C C 38 in 966 mm Including strain relief F D 35 in 889 mm F G H 4 Holes E 1 1 4 in 32 mm 4 Holes F 21 1 8 in 537 mm D G 1 1 8 in 29 mm D H 7 16 in 11 m...

Страница 20: ...ntary Protector CB1 3 Supplementary Protector CB2 CB1 protects 115 volts ac portion of RC8 1T and RC9 from overload CB2 protects 24 volts ac portion of RC8 and 1T from overload Press button to reset p...

Страница 21: ...age sense wire is 12 gauge or larger For better performance for most Sub Arc SAW applica tions make connections to the Submerged Arc weld output terminal Polarity For DCEP Reverse Polarity connect we...

Страница 22: ...ote control Turn on welding power source flux system wire drive assembly and HDC Sub Arc controller When Control switch is in Remote position Adjust control does not function Set desired preset voltag...

Страница 23: ...se leads detect arc voltage ac curately Best starts arcs and most reliable results BAD Sense lead is affected by weld current Due to voltage drops across work piece arc voltage may be low causing need...

Страница 24: ...need for deviation from standard procedures BAD Current flow from lead affects trail sense Current flow from trail affects lead sense Neither sense lead picks up the correct work voltage causing star...

Страница 25: ...0 800 4 0 2 2 0 2 3 0 2 4 0 3 4 0 3 4 0 4 4 0 4 4 0 900 2 2 0 2 3 0 2 4 0 3 3 0 3 4 0 4 4 0 4 4 0 1000 2 2 0 2 3 0 2 4 0 3 3 0 4 3 0 4 4 0 1250 2 3 0 2 4 0 3 3 0 4 3 0 4 4 0 Weld cable size AWG is bas...

Страница 26: ...eceptacle RC8 Connect remote control to RC8 If plug does not fit wire cord to terminal strip 1T Turn Off power before open ing terminal strip cover 2 Terminal Strip 1T 3 Remote Control Cord 4 Strain R...

Страница 27: ...uit breaker with time current curves comparable to the recommended fuse 2 Time Delay fuses are UL class RK5 3 Normal Operating general purpose no intentional delay fuses are UL class K5 up to and incl...

Страница 28: ...d Current Sensor Optional Connect green or green yellow grounding conductor to welding power source ground ing terminal first If unit is equipped with op tional ground current sensor route ground ing...

Страница 29: ...position digital meters will read 0 zero with contactor off Digital me ters will display actual output voltage and amperage with contactor on With Process Selector switch in the Constant Voltage posit...

Страница 30: ...unreadable labels Clean and tighten weld terminals Repair or replace cracked weld cable 6 Months Blow out or vacuum inside During heavy service clean monthly OR 6 2 Fuse F1 Ref 802 295 Turn Off power...

Страница 31: ...d tighten all weld output connections Unit provides only maximum or minimum weld output Have Factory Authorized Service Agent check control board PC1 and hall device HD1 minimum weld output Check posi...

Страница 32: ...OM 2223 Page 28 SECTION 7 ELECTRICAL DIAGRAM Figure 7 1 Circuit Diagram...

Страница 33: ...OM 2223 Page 29 236 682 A...

Страница 34: ...30 SECTION 8 PARTS LIST 802 296 D Figure 8 1 Main Assembly Hardware is common and not available unless listed 33 25 32 31 27 28 1 3 4 5 6 2 4 5 26 13 14 15 3 25 22 24 23 1 19 12 8 37 17 11 18 16 10 7...

Страница 35: ...40 750 SWITCH reed 1 24 W 193 473 CONTACTOR size 3 1 2 3P 24VAC 1 25 217 136 LABEL warning electric shock 2 26 193 462 BRACKET contactor mount 1 27 163 359 BASE 1 28 T1 218 414 TRANSFORMER pwr main 23...

Страница 36: ...LG5 152 249 CONNECTOR SOCKETS 1 PLG16 158 719 CONNECTOR SOCKETS 1 3 CR3 052 964 RELAY encl 24VDC DPDT 1 4 CR5 006 393 RELAY encl 24VAC DPDT 1 5 CB1 2 093 995 SUPPLEMENTARY PROTECTOR man reset 1P 15A 2...

Страница 37: ...IT CARD ASSY display w program 1 PLG10 153 501 CONNECTOR SOCKETS 1 PLG11 148 439 CONNECTOR SOCKETS 1 27 CR2 116 592 RELAY encl 24VDC 3PDT 1 28 192 174 STAND OFF 4 29 193 704 PANEL front upper 1 NAMEPL...

Страница 38: ...ckey puck 6 6 191 247 HEAT SINK rectifier snowflake3 000 3 7 191 246 CLAMP thyristor rectifier 8 187 3 PLG1 158 720 CONNECTOR SOCKETS 1 TP3 192 731 THERMOSTAT rectifier 1 TP6 168 894 THERMOSTAT rectif...

Страница 39: ...97 459 RESISTOR WW fxd 375W 20 ohm for units w o low ocv 1 8 FM 032 605 MOTOR 1 4HP 230VAC 1625RPM 50 60Hz 1 9 183 167 CONNECTOR clamp cable 2 000 1 802 298 C Hardware is common and not available unle...

Страница 40: ...Notes...

Страница 41: ...Notes...

Страница 42: ...Notes...

Страница 43: ...nduction Heating Coils and Blankets Cables and Non Electronic Controls APT SAF Model Plasma Cutting Torches Remote Controls Accessory Kits Replacement Parts No labor Spoolmate Spoolguns Canvas Covers...

Страница 44: ...retain with your personal records Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Supplies and Consumables Options and Accessories Personal...

Отзывы: