Complete Parts List available at www. MillerWelds.com
OM-228 042 Page 31
SECTION 8
−
MAINTENANCE
8-1. Power Source Routine Maintenance
Follow the storage procedure in the engine owner’s manual if the unit will not be used for an extended period.
Stop engine before maintaining.
See Engine Manual and Maintenance Label
for important start-up, service, and storage
information. Service engine more often if
used in severe conditions.
Recycle engine
fluids.
= Check
= Change
= Clean
= Replace
* To be done by Factory Authorized Service Agent
Reference
Every
8
Hours
Section 5-3
Fuel Level
Oil Level
Oil, Fuel Spills
Every
25
Hours
Section 8-9
Air Cleaner Precleaner
Every
50
Hours
Weld Terminals
Every
100
Hours
Engine
Manual,
Section 8-9
Oil
Air Cleaner Element
Cooling System
Spark Plug Gap
Battery Terminals
(Electric Start Models)
Every
200
Hours
Unreadable Labels
Every
300
Hours
Engine
Manual
Valve Clearance*
Every
500
Hours
Engine
Manual
Weld Cables
Slip Rings*
Brushes*
Every
1000
Hours
OR
Inside Unit