OM-808 Page 13
3-4.
Weld Input/Output Cables For Multi-Grid Rack
S-0799-A
1
Weld Input Cable
2
Work Cable
3
Weld Output Cable
If necessary, use Section 3-7 to
select proper cable size.
Use shortest cables possible.
Do not use damaged cables.
4
Terminal Lug
Use lugs of proper amperage ca-
pacity and hole size for connecting
to common work, electrode hold-
er(s), and weld output terminals (if
applicable).
5
Common Work Connection
Connect work cable to common
work according to codes.
6
Input Terminal
For models with polarity reversing,
connect positive and negative
cables to matching input terminal.
For models without polarity revers-
ing, only one input terminal is pro-
vided. Connect electrode cable to
input terminal.
7
Insulated Electrode Holder
8
GTAW Torch
Install according to manufacturer’s
instructions.
9
Male Camlok Connector
Install onto weld output cable as
shown in Section 3-6.
10 Electrode Receptacle
Connect electrode holder cable to
Electrode receptacle.
Tools Needed:
Or
7
8
4
9
3
4
1
5
6
4
10
2
Y
Turn Off welding power source, and disconnect input
power before making any weld output connections.
Содержание MOG-250