background image

OM-808 Page 8

1-4.

Principales normes de sécurité

Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel-
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126

Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.

Recommended Safe Practice for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances,
 norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126

National Electrical Code, NFPA Standard 70, de la National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.

Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.

Safe Practices For Occupation And Educational Eye And Face Protec-
tion
, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.

Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.

1-5.

Information sur les champs électromagnétiques

Données sur le soudage électrique et sur les effets, pour l’organisme,
des champs magnétiques basse fréquence

Le courant de soudage, pendant son passage dans les câbles de sou-
dage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir ex-
aminé plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National Re-
search Council a conclu: “L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiques et champs électriques à haute fréquence représente un
risque à la santé humaine”. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les con-
clusions finales de la recherche soient établies, il vous serait
souhaitable de réduire votre exposition aux champs électromagnéti-
ques pendant le soudage ou le coupage.

Afin de réduire les champs électromagnétiques dans l’environnement
de travail, respecter les consignes suivantes :

1

Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.

2

Mettre tous les câbles du côté opposé de l’opérateur.

3

Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.

4

Garder le poste de soudage et les câbles le plus loin possible de
vous.

5

Relier la pince de masse le plus près possible de la zone de
soudure.

Consignes relatives aux stimulateurs cardiaques :

Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est
alors recommandé de respecter les consignes ci–dessus.

Содержание MOG-250

Страница 1: ...W Welding Stick SMAW Welding Multiple Operator Resistance Grids MOG Racks And Remote Controls OM 808 081 904F January 1997 MOG 250 250 MOG 300 MOG 350 350 MOG 400 MOG Pak And RGC Controls Visit our we...

Страница 2: ...alue established in 1929 This Owner s Manual is designed to help you get the most out of your Miller products Please take time to read the Safety precautions They will help you protect yourself agains...

Страница 3: ...Operator System Component Relationships 10 3 2 Selecting A Location And Moving Resistance Grid Or Multi Grid Rack 11 3 3 Weld Input Output Cables For Resistance Grid Dual Model Shown 12 3 4 Weld Input...

Страница 4: ......

Страница 5: ...connected to a properly grounded receptacle outlet D When making input connections attach proper grounding conduc tor first double check connections D Frequently inspect input power cord for damage or...

Страница 6: ...lding wire at contact tip when not in use D Wear oil free protective garments such as leather gloves heavy shirt cuffless trousers high shoes and a cap D Remove any combustibles such as a butane light...

Страница 7: ...intained D Keep high frequency source doors and panels tightly shut keep spark gaps at correct setting and use grounding and shielding to minimize the possibility of interference ARC WELDING can cause...

Страница 8: ...a human health hazard However studies are still going forth and evidence continues to be examined Until the final conclusions of the research are reached you may wish to minimize your exposure to ele...

Страница 9: ...e de terre du sectionneur ou que la fiche du cordon est raccord e une prise correctement mise la terre D En effectuant les raccordements d entr e fixer d abord le conducteur de mise la terre appropri...

Страница 10: ...des v tements de protection d pourvus d huile tels que des gants en cuir une chemise en mat riau lourd des pantalons sans re vers des chaussures hautes et un couvre chef D Avant de souder retirer tou...

Страница 11: ...vrements et dispositifs de protection LE RAYONNEMENT HAUTE FR QUENCE H F risque de provoquer des interf rences D Le rayonnement haute frequence peut provoquer des interf rences avec les quipements de...

Страница 12: ...hamps magn tiques basse fr quence Le courant de soudage pendant son passage dans les c bles de sou dage causera des champs lectromagn tiques Il y a eu et il y a encore un certain souci propos de tels...

Страница 13: ...395 Amperes 100 Duty Cycle 245 A 490 A If Paralleled 100 Duty Cycle 345 A 690 A If Paralleled 100 Duty Cycle Net Weight With Case 65 lb 20 kg W O Case 50 lb 23 kg With Case 72 lb 33 kg W O Case 57 lb...

Страница 14: ...lectrical parts Do not touch electrode holders of opposite polarity at the same time Separate electrode holders of opposite polarity to prevent contact Consult ANSI Z49 1 for common grounding safe pra...

Страница 15: ...stance Grid 1 18 in 460 mm Open Space On Front Side Location should allow operation of controls 2 Handles Use handles to lift unit Multi Grid Rack 3 Minimum 20 in 508 mm Open Space On Front And Rear S...

Страница 16: ...ting to common work electrode hold er s and weld output terminals if applicable 5 Common Work Connection Connect work cable to common work according to codes 6 Insulated Electrode Holder 7 GTAW Torch...

Страница 17: ...work according to codes 6 Input Terminal For models with polarity reversing connect positive and negative cables to matching input terminal For models without polarity revers ing only one input termin...

Страница 18: ...over connector body so holes align secure by tapping pin into place 1 2 3 4 5 6 1 in 26 mm Tools Needed 7 32 in 3 6 Male Camlok Connector Assembly sb6 4 11 92 ST 155 015 1 Weld Output Cable Strip insu...

Страница 19: ...3 0 4 0 2 2 0 2 3 0 2 4 0 3 3 0 3 3 0 600 3 0 4 0 2 2 0 2 3 0 2 4 0 3 3 0 3 4 0 3 4 0 700 4 0 2 2 0 2 3 0 2 4 0 3 3 0 3 4 0 3 4 0 4 4 0 800 4 0 2 2 0 2 3 0 2 4 0 3 4 0 3 4 0 4 4 0 4 4 0 Weld cable siz...

Страница 20: ...Subpart Q 4 1 Controls Dual Model Shown Ref ST 161 155 1 Coarse Amperage Control 2 Paralleling Switch Included on dual models only 3 Optional Polarity Switch 4 2 1 2 Ampere Switch This switch is inclu...

Страница 21: ...Do not touch live electrical parts Do not touch electrode holders of opposite polarity at the same time Separate electrode holders of opposite polarity to prevent contact See ANSI Z49 1 and OSHA TITLE...

Страница 22: ...amperage using only the Fine Amperage control place Coarse Amperage control in Off position 2 2 1 2 Ampere Switch Optional Use switch to add 2 1 2 amperes to weld output To add 2 1 2 amperes to weld...

Страница 23: ...ce switch in On position For front panel amperage adjust ment place control in Off position 3 2 1 4 7 Paralleling Switch Dual Models Only CAUTION ARCING can damage switch Do not change Paralleling swi...

Страница 24: ...Connect Equipment If Applicable Install High_ Frequency Unit Select Tungsten Insert Tungsten Into Torch Put On Personal Safety Equipment Set Controls If Applicable Turn On High Frequency Unit Turn On...

Страница 25: ...oor Grid Rear Panel Multi Grid Rack 1 5 3 Troubleshooting Trouble Remedy No weld output Check and replace open fuse link s if necessary see Section 5 2 Check electrical input and output connections se...

Страница 26: ...OM 808 Page 22 SECTION 6 ELECTRICAL DIAGRAMS SA 044 882 A Figure 6 1 Circuit Diagram For 300 Ampere Model SA 096 447 A Figure 6 2 Circuit Diagram For 300 Ampere Model With Polarity Reversing...

Страница 27: ...OM 808 Page 23 SA 044 884 A Figure 6 3 Circuit Diagram For 400 Ampere Model SA 096 445 A Figure 6 4 Circuit Diagram For 400 Ampere Model With Polarity Reversing...

Страница 28: ...OM 808 Page 24 SA 044 886 A Figure 6 5 Circuit Diagram For 250 250 Ampere Model SB 124 202 Figure 6 6 Circuit Diagram For 250 250 Ampere Model With Polarity Reversing...

Страница 29: ...OM 808 Page 25 SA 087 783 A Figure 6 7 Circuit Diagram For 350 350 Ampere Model SA 095 027 A Figure 6 8 Circuit Diagram For Remote Grid Controls...

Страница 30: ...ON 7 PARTS LIST ST 124 640 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 16 15 19 13 20 10 21 22 23 6 24 1 25 26 27 28 29 30 Fig 7 2 31 Fig 7 3 Hardware is common and not available unless listed Figu...

Страница 31: ...8 BUS BAR common 1 4 x 1 x 11 7 8 1 1 1 1 12 059 805 TUBING cop 540 OD x 123 wall x 5 16 1 1 1 1 1 1 13 010 907 NUT locking 1 in 1 1 1 1 13 010 907 NUT locking 1 in 2 2 2 14 010 854 NUT speed No 2 1 1...

Страница 32: ...r by ft 3ft 600 323 CABLE weld No 3 also 250 250BPR 400APR order by ft 3ft 3ft 3ft PR models only Recommended Spare Parts When ordering a component originally displaying a precautionary label the labe...

Страница 33: ...pplicable 1 1 1 1 12 059 872 TUBING 3 8 OD x 0 256 ID x 2 1 2 2 2 2 2 13 049 568 BUS BAR output 1 8 x 1 x 5 9 16 1 1 1 1 14 049 569 BUS BAR interconnect 1 8 x 1 x 2 1 4 1 1 1 1 15 049 485 BAFFLE front...

Страница 34: ...28 36 48 64 059 728 INSULATOR support 22 30 36 52 059 727 INSULATOR support 5 8 bore 6 6 12 12 059 724 RING retaining ext 886 x 0 021 34 42 60 76 059 725 RING retaining ext 1 379 x 0 025 22 30 36 52 4...

Страница 35: ...2 2 4 13 R8 059 932 RESISTOR WW fxd 175W 20 ohm 1 13 R9 059 932 RESISTOR WW fxd 175W 20 ohm 1 13 R15 16 059 932 RESISTOR WW fxd 175W 20 ohm 2 14 R2 3 059 798 RESISTOR 10A 2 2 14 R5 6 12 13 059 798 RES...

Страница 36: ...OM 808 Page 32 SD 080 254 E 1 2 3 4 5 6 7 8 9 10 11 12 Hardware is common and not available unless listed Figure 7 4 MOG Pak 6 APR...

Страница 37: ...2 1 1 1 2 601 879 NUT brs hex full 1 2 13 2 2 1 2 1 2 7 049 767 PANEL rear 1 1 7 049 703 PANEL rear 1 1 7 049 536 PANEL rear 1 1 8 027 529 PIN cotter 1 4 x 3 1 2 2 2 2 2 3 3 9 049 766 PANEL rear 1 1...

Страница 38: ...080 198 CASE SECTION base front rear 1 1 NAMEPLATE order by model number 1 1 6 006 790 KNOB switch 1 1 059 734 SWITCH current 1 1 7 053 359 SWITCH tgl SPST 20A 125V 1 1 SA 080 370 A 2 4 5 6 7 3 1 Hard...

Страница 39: ...ting Torches Remote Controls Accessory Kits Replacement Parts No labor Spoolmate 185 Spoolmate 250 Canvas Covers Miller s True Blue Limited Warranty shall not apply to 1 Consumable components such as...

Страница 40: ...complete and retain with your personal records Always provide Model Name and Serial Style Number Call 1 800 4 A Miller or see our website at www MillerWelds com to locate a DISTRIBUTOR or SERVICE AGEN...

Отзывы: