20
OM-402
4.6
Remote 14 Receptacle RC1 Information
Ref. ST-158 93
Socket*
Socket Information
A
24 volt ac with respect to socket G. Protected by circuit
breaker CB5.
B
Contact closure to A completes 24 volt ac contactor
control circuit.
A
J
B
K
I
G
Circuit common for 24 volt ac circuit.
B
K
I
C L N
H
D M
G
F
C
0 to +10 volts dc output to remote control with respect
to socket D.
E
F
A
D
Remote control circuit common.
A
E
0 to +10 volts dc input command signal from remote
control with respect to socket D.
K
Chassis common.
*The remaining sockets are not used.