TM-428 Page 13
Miller Legend
13 Remote Control Switch S4
Selects Panel or remote amperage
control.
14 Circuit Breakers CB1, CB2,
CB5, And CB7
Protect 50/60 Hz auxiliary power
receptacles RC1, RC2, and RC3
from overload.
15 50/60 Hz Auxiliary Power Re-
ceptacles RC1, RC2, And
RC3
Provide connection points and
power for auxiliary equipment.
16 Circuit Breaker CB3
Protects 100 Hz auxiliary power re-
ceptacle RC4 from overload.
17 100 Hz Auxiliary Power Re-
ceptacle RC4
Provides connection point and
power for auxiliary equipment
while welding.
18 Fine Amperage Control R1
Adjusts amperage within range se-
lected by Ampere Ranges switch
S5.
19 Ampere Ranges Switch S5
Selects coarse range of weld out-
put from weld stator.
20 Reactor AC-Z
Tapped reactor limits weld output
and provides coarse ranges.
21 Main Rectifier SR1
Changes ac output from weld
windings to dc.
22 Stabilizer DC-Z
Smooths out current to dc weld
output terminals.
23 HF Filter Board PC4
Protects unit from high frequency.
24 Positive (+) And Negative (–)
DC Weld Output Terminals
Provide dc weld output.
25 Electrode And Work AC Weld
Output Terminals
Provide ac weld output.
Stabilizer
Main
Rectifier
SR1
Ampere
Ranges
Switch S5
Reactor
AC-Z
DC-Z
HF Filter
Board
PC4
Positive (+) And
Negative (–) DC
Weld Output
Terminals
Transformer
T1
Circuit
Breakers
CB1, CB2,
50/60 Hz
Auxiliary Power
Receptacles
RC1, RC2, RC3
19
20
21
22
11
14
15
23
25
24
Electrode And
Work AC Weld
Output Terminals
AC Or DC Control Circuits
Mechanical Coupling
Weld Current Circuit
Magnetic Coupling
♦
Optional
CR4
CB5, CB7