OM-481 Page 20
6-2.
240 Volt Duplex Receptacle (Optional)
Ref. ST-174 733 / ST-174 757
If unit does not have GFCI recep-
tacles, use GFCI-protected exten-
sion cord.
1
240 V 15 A AC Duplex
Receptacle RC1
Receptacle supplies 60 Hz single-phase
power at weld/power speed. Maximum out-
put from this receptacle is 3 kVA/kW.
2
120 V 20 A AC Duplex Receptacle
GFCI2 (Section 6-1)
3
Circuit Breakers CB1 And CB2
CB1 and CB2 protect the 120 V and 240 V
receptacles from overload. If CB1 or CB2
opens, the 240 V receptacle and one half of
the 120 V receptacle does not work. 120
volts may still be present at the 240 volt re-
ceptacle. Press button to reset breaker.
If a circuit breaker continues to open,
contact a Factory Authorized Service
Agent.
4
Total Generator Power Output
Combined output of all receptacles limited
to 3 kVA/kW output of the generator.
EXAMPLE: If 10 A is drawn from the 240 V
receptacle, only 5 A is available at the 120
V receptacle:
(240 V x 10 A) + (120 V x 5 A) = 3.0 kVA/kW
1
3
4
2
SECTION 7 – MAINTENANCE & TROUBLESHOOTING
7-1.
Routine Maintenance
Follow the storage procedure in the engine owner’s manual if the unit will not be used for an
extended period.
Note
Recycle engine
fluids.
Stop engine before maintaining.
See also Engine Manual and Mainte-
nance Label. Service engine more often
if used in severe conditions.
*
To be done by Factory Authorized
Service Agent.
8 h
Check Fluid
Levels. See
Section 4-4.
Wipe
Up
Spills.
OIL
Full
Drain Water
From Fuel
System.
FUEL
WATER
50 h
Clean Air Filter.
See Section 7-3.
Clean And
Tighten
Weld
Terminals.