OM-173 413 Page 29
7-3.
Servicing Air Cleaner
aircleaner4 9/99– 802 495 / Ref. S-0698-B
Stop engine.
1
Air Cleaner
2
Service Indicator (Optional)
3
Window
4
Reset Button
Service air cleaner element if red
band appears in window. A green
band means air cleaner is okay.
Press button to reset indicator.
Do not run engine without air
cleaner or with dirty element.
Clean or replace element if dirty or
damaged. Replace element yearly
or after six cleanings.
5
Dust Ejector
6
Dust Cover
7
Element
8
Safety Element (Optional)
9
Body
To Clean air filter:
Wipe off cover and body. Remove
cover and dump out dust. Wipe dust
from inside cover and body with
damp cloth. Remove element(s)
and reinstall cover.
Do not clean air cleaner body
with air hose.
Clean element(s) with compressed
air only. Keep nozzle at least 1 in
(25 mm) from inside of element.
Max. air pressure: 100 psi (690
kPa). Replace element(s) if it has
holes or damaged gaskets.
Reinstall element(s) and cover
(dust ejector down)
2
3
4
1
Blow
Inspect
5
6
7
9
8