2-5.

Principales normes de sécurité

Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
de Global Engineering Documents (téléphone : 1-877-413-5184, site
Internet : www.global.ihs.com).

Recommended Safe Practices for the Preparation for Welding and Cut-
ting of Containers and Piping
, American Welding Society Standard
AWS F4.1 de Global Engineering Documents (téléphone :
1-877-413-5184, site Internet : www.global.ihs.com).

National Electrical Code, NFPA Standard 70, de National Fire Protec-
tion Association, P.O. Box 9101, Quincy, MA 02269-9101 (téléphone :
617-770-3000, site Internet : www.nfpa.org).

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de Compressed Gas Association, 4221 Walney Road, 5th Floor, Chan-
tilly, VA 20151 (téléphone : 703-788-2700, site Internet :
www.cganet.com).

Code for Safety in Welding and Cutting, CSA Standard W117.2, de
Canadian Standards Association, 5060 Mississauga, Ontario, Canada

L4W 5NS (téléphone : 800-463-6727 ou à Toronto 416-747-4044, site
Internet : www.csa-international.org).

Safe Practice For Occupational And Educational Eye And Face Protec-
tion,
 ANSI Standard Z87.1, de American National Standards Institute,
11 West 43rd Street, New York, NY 10036-8002 (téléphone :
212-642-4900, site Internet : www.ansi.org).

Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work
, NFPA Standard 51B, de National Fire Protection Association,
P.O. Box 9101, Quincy, MA 02269-9101 (téléphone : 617-770-3000,
site Internet : www.nfpa.org).

OSHA, Occupational Safety and Health Standards for General Indus-
try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, de U.S. Government Printing Office, Superin-
tendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954
(téléphone : 1-866-512-1800) (il y a 10 bureaux régionaux−−le télépho-
ne de la région 5, Chicago, est 312-353-2220, site Internet :
www.osha.gov).

2-6.

Information EMF

Considérations sur le soudage et les effets de basse fréquence et des
champs magnétiques et électriques.
Le courant de soudage, pendant son passage dans les câbles de sou-
dage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir exa-
miné plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National
Research Council a conclu : « L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiques et champs électriques à haute fréquence représente un
risque à la santé humaine ». Toutefois, des études sont toujours en
cours et les preuves continuent à être examinées. En attendant que les
conclusions finales de la recherche soient établies, il vous serait
souhaitable de réduire votre exposition aux champs électromagnéti-
ques pendant le soudage ou le coupage.
Pour réduire les champs magnétiques sur le poste de travail, appliquer
les procédures suivantes :

1.

Garder les câbles ensemble, les torsader, les scotcher, ou les
recouvrir d’une housse.

2.

Disposer les câbles d’un côté et à distance de l’opérateur.

3.

Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.

4.

Garder le poste de soudage et les câbles le plus loin possible de
vous.

5.

Connecter la pince sur la pièce aussi près que possible de la
soudure.

En ce qui concerne les i

mplants médicaux :

Les porteurs d’implants doivent d’abord consulter leur médecin avant
de s’approcher des opérations de soudage à l’arc, de soudage par
points, de gougeage, du coupage plasma ou de chauffage par induc-
tion. Si le médecin approuve, il est recommandé de suivre les
procédures précédentes.

Содержание Axcess 450

Страница 1: ...9J 2007 10 Axcess 450 Processes Description MIG GMAW Welding Pulsed MIG GMAW P Flux Cored FCAW Welding Arc Welding Power Source File Advanced Manufacturing Systems Visit our website at www MillerWelds...

Страница 2: ...tinue the tradition They re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929 This Owner s Manual is designed to help you get...

Страница 3: ...STALLATION 14 4 1 Specifications 14 4 2 Dimensions And Weight 14 4 3 Duty Cycle And Overheating 15 4 4 Volt Ampere Curves 15 4 5 Selecting A Location 16 4 6 Connection Diagram 16 4 7 Rear Panel Recept...

Страница 4: ...easuring Input Capacitor Voltage 32 9 2 Process Control Module PC4 Diagnostic LED s 33 9 3 Diagnostic LED s On Process Control Module PC4 33 9 4 Network And Module Status LED s 34 9 5 Troubleshooting...

Страница 5: ...this product AxcessE 450 conforms to the following Directives and Standards Directives Low Voltage Directive 73 23 EEC Electromagnetic Compatibility Directives 89 336 EEC 92 31 EEC 2004 108 EC Machin...

Страница 6: ......

Страница 7: ...cramped positions such as sitting kneeling or lying or when there is a high risk of unavoid able or accidental contact with the workpiece or ground For these conditions use the following equipment in...

Страница 8: ...s they are properly prepared according to AWS F4 1 see Safety Standards D Do not weld where the atmosphere may contain flammable dust gas or liquid vapors such as gasoline D Connect work cable to the...

Страница 9: ...ans D Keep all doors panels covers and guards closed and securely in place D Have only qualified persons remove doors panels covers or guards for maintenance as necessary D Reinstall doors panels cove...

Страница 10: ...York NY 10036 8002 phone 212 642 4900 website www ansi org Standard for Fire Prevention During Welding Cutting and Other Hot Work NFPA Standard 51B from National Fire Protection Association P O Box 91...

Страница 11: ...source lectrique courant lectrique s av re n cessaire se servir de la fonction de t l commande si l appareil en est quip D D autres consignes de s curit sont n cessaires dans les condi tions suivante...

Страница 12: ...de protection LE SOUDAGE peut provoquer un in cendie ou une explosion Le soudage effectu sur des conteneurs ferm s tels que des r servoirs tambours ou des conduites peu provoquer leur clatement Des ti...

Страница 13: ...e pour usage ult rieur D Utiliser les quipements corrects les bonnes proc dures et suffi samment de personnes pour soulever et d placer les bouteilles D Lire et suivre les instructions sur les bouteil...

Страница 14: ...de provoquer des interf rences D L nergie lectromagn tique risque de provo quer des interf rences pour l quipement lec tronique sensible tel que les ordinateurs et l quipement command par ordinateur t...

Страница 15: ...O Box 371954 Pittsburgh PA 15250 7954 t l phone 1 866 512 1800 il y a 10 bureaux r gionaux le t l pho ne de la r gion 5 Chicago est 312 353 2220 site Internet www osha gov 2 6 Information EMF Consid r...

Страница 16: ...OM 220 389 Page 10...

Страница 17: ...2 Use forced ventilation or local exhaust to remove the fumes 2 3 Use ventilating fan to remove fumes 3 Welding sparks can cause explosion or fire 3 1 Keep flammables away from welding Do not weld nea...

Страница 18: ...when servicing unit 9 Always wear long sleeves and button your collar when servicing unit 10 After taking proper precautions as shown connect power to unit 4 04 219 844 A 5 min V V V 1 2 3 4 5 6 7 8 9...

Страница 19: ...Connection Gas Metal Arc Welding GMAW Three Phase Static Frequency Con verter Transformer Rectifier U0 Rated No Load Voltage Average U1 Primary Voltage U2 Conventional Load Voltage X Duty Cycle Hz He...

Страница 20: ...m 1 3 35 6 mpm 030 062 in 0 8 1 6 mm 80 27 9 0 1A 19 46 0 8 18 68 0 17 While idling Input amperage fluctuates while idling and is always less than one Ampere Use one Ampere for power efficiency calcul...

Страница 21: ...y Overheating 0 15 A V OR Reduce Duty Cycle Minutes duty1 4 95 220 485 A Continuous Welding 100 Duty Cycle At 450 Amperes 60 Duty Cycle At 580 Amperes 6 Minutes Welding 4 Minutes Resting 4 4 Volt Ampe...

Страница 22: ...supply Movement 2 Location 4 18 in 460 mm 18 in 460 mm 3 Do not move or operate unit where it could tip Tipping 1 OR Special installation may be required where gasoline or volatile liquids are present...

Страница 23: ...1 protects 115 volt receptacle RC2 from overload If CB1 opens RC2 does not work CB2 protects the wirefeed motor from overload If CB2 opens the wirefeeder does not work Press button to reset breaker If...

Страница 24: ...ld Output Terminal 2 Negative Weld Output Terminal Connect positive weld cable to Positive weld terminal and negative cable to Negative weld terminal 3 Weld Output Terminal 4 Supplied Weld Output Term...

Страница 25: ...power to this welding power source Actual input voltage should not exceed 10 of indicated required input voltage If actual input voltage is outside of this range output may not be available 50 60 Hz...

Страница 26: ...pplicable use lugs of proper amperage capacity and correct hole size Welding Power Source Input Power Connections 2 Strain Relief Install strain relief of proper size for unit and input conductors Rou...

Страница 27: ...60 2 0 70 3 0 95 4 0 120 2 ea 2 0 2x70 2 ea 3 0 2x95 2 ea 3 0 2x95 2 ea 4 0 2x120 400 1 0 60 2 0 70 3 0 95 4 0 120 2 ea 2 0 2x70 2 ea 3 0 2x95 2 ea 4 0 2x120 2 ea 4 0 2x120 500 2 0 70 3 0 95 4 0 120...

Страница 28: ...ce with a standard welding circuit connection The length of a welding circuit is determinedas follows Welding Circuit Electrode Cable Length ECL Work Cable Length WCL Workpiece Length WL See Section 5...

Страница 29: ...y becomes enabled for all semi automatic processes The work sense lead connects to the Axcess welding power source 4 pin connector located above the negative output terminal This work sense lead autom...

Страница 30: ...elding gas regulator and shielding gas connection for each welding gun Arc blow is the deflection of a welding arc from its normal path due to magnetic forces It will adversely affect the appearanceof...

Страница 31: ...ent is a bad setup due to sensing leads being directly in the current flow path of the welding arc Interaction between welding circuits will affect voltage drop in the workpiece The voltage drop acros...

Страница 32: ...ing Lead 6 Wire Feeder 7 Workpiece This arrangement is a better setup for supporting separate voltage feedback to the welding power sources The most accurate voltage sensing may not be achieved due to...

Страница 33: ...Work Cable 5 Voltage Sensing Lead 6 Wire Feeder 7 Workpiece This arrangement is the best setup for proper voltage sensing at the workpiece Voltage feedback to the welding power sources will more accur...

Страница 34: ...ON 6 OPERATION 6 1 Front Panel Switches 1 2 Ref 803 418 B 1 Power Switch Turns unit On or Off 2 Pilot Light Light indicates status of welding power source on when unit is on and off when unit is off 3...

Страница 35: ...done by Factory Authorized Service Agent Reference Every Every 3 Months l Unreadable Labels Weld Terminals l Damaged Gas Hose nl Weld Cables 3 Months nl Cords nl Gun Cables Every 6 Months OR Drive Ro...

Страница 36: ...h the ground D Do not leave live unit unattended D If this procedure requires an energized unit have only personnel familiar with and following standard safety practices do the job D When testing a li...

Страница 37: ...lding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and in some cases cancer California Health Safety Code Section 25249...

Страница 38: ...ample of a typical bleeder resistor is shown on this page Proceed with job inside unit Reinstall cover when finished Tools Needed 5 16 in 802 985 Ref 803 419 B 900 Volts dc can be present on the capac...

Страница 39: ...PC4 Diagnostic LED s 1 LED2 LED1 LED4 LED3 9 3 Diagnostic LED s On Process Control Module PC4 LED Status Diagnosis 1 On Indicates 25 volts dc is present on process control module PC4 Off Indicates 25...

Страница 40: ...th the network Red The circuit board has encountered a communication link failure with the network Check DeviceNet cable connections Verify dip switch positions according to Sections 1 2 and 1 3 Repla...

Страница 41: ...ed Check circuit breaker CB2 and reset if necessary Check motor control cable connections Wire feeds erratically Readjust hub tension Readjust drive roll pressure Clean or replace dirty or worn drive...

Страница 42: ...OM 220 389 Page 36 SECTION 10 ELECTRICAL DIAGRAMS Figure 10 1 Circuit Diagram For Welding Power Source...

Страница 43: ...OM 220 389 Page 37 220 420 B...

Страница 44: ...ge 38 SECTION 11 PARTS LIST Hardware is common and not available unless listed Ref 803 856 B 2 3 6 7 5 9 11 10 15 14 15 9 1 12 13 4 Fig 11 3 5 Fig 11 2 8 Fig 11 4 16 Fig 11 5 17 19 18 18 Figure 11 1 M...

Страница 45: ...Input Filter 1 14 148025 Lug Univ W SCR 600V 2 0 6 Wire 266 Stud 1 15 213372 Filter Assy Secondary 2 16 Fig 11 5 Front Panel Assembly 1 227855 Kit Connectors W Washer For Power Cables Includes 1 17 0...

Страница 46: ...Vdc Can 2 50 Dia 2 22 210507 Clamp Capacitor Top Machined 2 23 217625 Kit Input Pre regulator And Inverter Module 1 24 RT1 RT2 214015 Thermistor NTC 30K Ohm 25 Deg C 7 18in Lead 1 25 PC2 222661 Circu...

Страница 47: ...2 Id X 1 500 Mtg Hole 1 4 PC4 204048 Circuit Card Assy Process Control Module 1 5 083147 Grommet SCR No 8 10 Panel Hole 312 Sq 500 High 8 6 210491 Panel Mtg Components Top 1 7 198122 Stand Off Support...

Страница 48: ...pplementary Protector Man Reset 1P 10A 250VAC Frict 1 7 CB2 093995 Supplementary Protector Man Reset 1P 15A 250VAC Frict 1 8 RC2 196814 Receptacle w Leads 115V Duplex 1 9 PC12 209676 Circuit Card Assy...

Страница 49: ...or Switch Power 1 3 211475 Plate front panel 1 4 PC13 208071 Circuit Card Assy ISO COMM 1 5 FM 196313 Fan Muffin 115V 50 60 Hz 3000 Rpm 6 378 Mtg Holes 2 6 C6 C7 C8 206878 Capacitor Assy 3 7 213102 Ch...

Страница 50: ...0 210865 Terminal Pwr Output Red 1 21 210483 Bracket lift eye 1 22 210358 Bolt eye shld thd stem 500 13 X 1 500 1 OPTIONAL When ordering a component originally displaying a precautionary label the lab...

Страница 51: ...nduction Heating Coils and Blankets Cables and Non Electronic Controls APT SAF Model Plasma Cutting Torches Remote Controls Accessory Kits Replacement Parts No labor Spoolmate Spoolguns Canvas Covers...

Страница 52: ...retain with your personal records Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Supplies and Consumables Options and Accessories Personal...

Отзывы: