IMAGE 2.  RBAND GATE EDGE RECEIVER PCB & CONNECTIONS

LED INDICATORS 

R1 & R2 RELAY LEDS
• 

O

n: No transmitters programmed

• 

Off: Programmed

• 

On (transmitters programmed): 
Fault condition

R3 RELAY LED
• 

On when battery is low

A TEST LED 
• 

On when in test mode

CHECK LED  
(both channels programed)
• 

Programmed: Check LED flashes 
every 5 seconds

DIP SWITCH SETTINGS

ON

1 2 3 4

 

Switch 1-3: Leave switches in factory 
default settings

 

Switch 4: Used to enable Normally 
Closed cycle testing: 
• 

10K Operator: Set to 

off

• 

N.C. Operator: Set to 

on and 

connect the switched power to the 
A Test and Common pins shown 
above [TABLE 2]

GND ANT

R2

R1

R3 A TEST

CHECK

PROG

ON

1 2 3 4

12/24 AC/DC

CS1 C1

+

-

BS1

CS2 C2

BS2

NO3

C3

COM. A TEST

MR

PROGRAM 

BUTTON

CHECK LED  

&  BUTTON

REMOVABLE 

8-PIN CONNECTOR

DIP

SWITCHES

RELAY 

LEDS

ANTENNA  

TERMINAL 

BLOCK

REMOVABLE 

4-PIN CONNECTOR

COAXIAL CABLE 
PROVIDED BY 
INSTALLER

ANTENNA

F-CONNECTOR  

COAX EXTENDER

MR

Содержание Rband RB-G-K10

Страница 1: ... Edge Transmitter RB TX10 RBand Gate Edge Receiver RB G RX10 Receiver antenna 2 3 6V AA lithium batteries 4 6 pan head transmitter mounting screws RB TX10 Contents RBand Gate Edge Transmitter RB TX10 2 3 6V AA lithium batteries 4 6 pan head transmitter mounting screws Replacement 3 6V AA lithium batteries can be purchased at your local electronics store or via Miller Edge Required 1 8 flat blade s...

Страница 2: ...4 PIN CONNECTOR Relay Output 3 NO3 Low battery alarm optional C3 Low battery alarm optional N C Power Cycling COM COM Switched power Common A TEST 12 24VDC Switched power source TABLE 2 NORMALLY CLOSED OPERATORS Removable Connector Assignments by Manufacturer HySecurity ON 1 2 3 4 DIP Switch 4 On to run Off to test CS1 C1 BS1 CS2 C2 BS2 NO3 C3 COM ATEST 12 24 AC DC SENSOR COMMON COMMON not sensor ...

Страница 3: ...s DIP SWITCH SETTINGS ON 1 2 3 4 Switch 1 3 Leave switches in factory default settings Switch 4 Used to enable Normally Closed cycle testing 10K Operator Set to off N C Operator Set to on and connect the switched power to the A Test and Common pins shown above TABLE 2 GND ANT R2 R1 R3 A TEST CHECK PROG ON 1 2 3 4 12 24 AC DC CS1 C1 BS1 CS2 C2 BS2 NO3 C3 COM ATEST MR PROGRAM BUTTON CHECK LED BUTTON...

Страница 4: ...f outer covering of sensing edge cable then feed through the Transmitter strain relief fitting Connect the two sensing edge wires to the removable terminal Dress the wires with a small service loop and tighten the strain relief Mount unit utilizing the mounting holes at the 4 corners of the Transmitter box Affix lid to the Transmitter noting the alignment pin IMAGE 3 Note Altering the NEMA 4 Trans...

Страница 5: ...10K termination Relay Output 3 2 Relay closes when low battery is detected A TEST 2 Connect to switched DC power and Com for N C monitoring 8 FCC COMPLIANCE RBAND EDGE TRANSMITTER Model RB TX10 FCC ID U5Z RB TX10 This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any ...

Отзывы: