background image

TCL-2

SAFETY PRECAUTIONS

For your safety and the safety of others, be sure to read and understand all safety and opera-

tional instructions before attempting to use the TCL-2. 

WARNING: The TCL-2 internal cir-

cuitry carries lethal voltages.

 Carefully observe all warnings, precautions, and instructions on 

the TCL-2 and as described in the instructions supplied with the unit.

1. WATER, MOISTURE, AND SPILLAGE

Do not attempt to use the TCL-2 in, near, or around water or in unusually moist environments, 
such as near a sink or swimming pool. Prevent liquids or any other materials or objects from spill-

ing or falling into the TCL-2 unit. 

2. HEAT AND VENTILATION 

Be sure to allow adequate ventilation to TCL-2 and avoid using or installing unit in close proxim-
ity to heat sources, such as heaters, stoves, radiators, power amplifiers, spotlights, or other heat-

producing appliances or equipment. 

3. POWER SOURCES AND POWER CORD PROTECTION

The TCL-2 Power Supply should be connected to a power source only of the type described in 
the operating instructions or as marked on the Power Supply. Route the power cord so that it is 
not likely to be walked on or pinched by having objects placed on it. Pay particular attention to 
plugs, receptacles, and the point where the AC power cord exits the TCL-2.

4. GROUNDING
For your safety, it is extremely important that the grounding pin of the 3-wire power cable (in-
cluded with unit) be inserted into a grounding type 3-pin power outlet. If you are unable to insert 
the plug into an existing outlet, contact an electrician to install a properly grounded 3-pin power 
outlet, preferably with OFI protection.

5. DAMAGE REQUIRING SERVICE
This unit should be repaired or serviced by qualified personnel whenever:
· The AC power cord has been damaged, or
· Objects have fallen or liquid has spilled into any TCL-2 unit, or
· The unit does not function properly or exhibits a marked change in performance, or
· The unit has been abused, dropped, or damaged, or
· The unit has been exposed to rain or moisture

6. SERVICING

Lethal voltages are found inside the TCL-2 chassis.

 The user should not attempt to repair or service 

this unit. All servicing and/or repairs should be referred to Millennia Media. 

If, after reading all instructions, precautions, and warnings, you have remaining questions, please 
contact Millennia Media directly before attempting to use your TCL-2. Retain this owner’s manual 
as a record of your purchase to aid positive identification in the event of loss.

Содержание TCL-2

Страница 1: ...l contained in this manual consists of information that is property of Millennia Media Inc and is intended solely for use by the purchasers of the equipment described in this manual Millennia Media Inc expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation and or maintenance of the equip ment described in this manual without th...

Страница 2: ... on or pinched by having objects placed on it Pay particular attention to plugs receptacles and the point where the AC power cord exits the TCL 2 4 GROUNDING For your safety it is extremely important that the grounding pin of the 3 wire power cable in cluded with unit be inserted into a grounding type 3 pin power outlet If you are unable to insert the plug into an existing outlet contact an electr...

Страница 3: ...ure that the rear panel voltage selection fuse block switch is set correctly In the USA the TCL 2 is shipped with the voltage selection block set to 100 120 VAC At this voltage setting a pair of 1 amp 5 x 20 mm slow blow fuses have been factory installed If you change the voltage selection block to 200 240 VAC usage be sure to change both fuses to 500 milliamp 0 4 amp slow blow types The TCL 2 enc...

Страница 4: ...The fuse block contains two fuses one fuse is in series with the hot power line while the other fuse is in series with the neutral power line Both fuses must be installed To change the mains voltage selection remove IEC power connector and assure that the TCL 2 is not connected to mains power With a non conductive tool gently pry the fuse block away from the power entry module Remove the two fuses...

Страница 5: ... TCL 2 1 2 4 5 3 GROUND LIFT PUSH PUSH 115 IN 2 OUT 2 IN 1 OUT 1 TCL 2 Twincom Rear Panel ______________ 1 2 4 5 3 ...

Страница 6: ...ch selects channel status When switch is depressed and corresponding LED is illuminated audio signal will be processed by dynamics functions When switch is not depressed and LED is not illuminated audio signal is not processed by dynamics functions This is not a hard wire bypass Audio signal is always in the active circuit path regardless of this switch s status 6 METER FUNCTION SELECT SWITCH METE...

Страница 7: ... TCL 2 TCL 2 Twincom Rear Panel ______________ ...

Страница 8: ... desired about of GR as shown on the meter E Depress the Stereo Link switch Note the amount of GR shown on the meter will probably decrease Simply increase the threshold until you again achieve the desired about of GR as shown on the meter F You should now see the same amount of GR on BOTH meters If you do not adjust the ratio control s on one or both channels until you do 10 METER ZERO ADJUST MET...

Страница 9: ... ohms VT or SS 5 ohms 300 ohms 300 ohms SS 3 000 ohms VT 87 dBu SS 82 dBu VT 50 dB 75 dB typical lOOmV to 20 kHz Pin 2 positive polarity Pin 1 ground 20 dBu to 20 dBu continuously adjustable 2 mS to 100 mS continuously adjustable 00 mS to 3 0 sec continuously adjustable Min 1 4 to 1 Max 30 to 1 continuous Yes Yes Yes Switch In FET Amplifiers Switch Out Vacuum Tube Amplifiers ELECTRO MECHANICAL SPE...

Страница 10: ... goal of absolute sonic neutrality and timbre purity 1 No audio transformers The vast majority of professional vacuum tube audio equipment uses audio transformers Yet as someone once said there is no transformer that sounds like no transformer For this reason Millennia avoids audio path transformers and relies on other less colorful coupling techniques 2 Lower tighter gain and threshold structure ...

Страница 11: ...PUT LEVEL OUTPUT LEVEL CH IN CH IN METER ON GR METER ON GR STEREO LINK TT TT VU 20 10 7 5 3 3 2 2 1 1 0 VU 20 10 7 5 3 3 2 2 1 1 0 Millennia Music Media Systems TCL 2 Template DATE PROJECT STUDIO ARTIST SONG LOG NOTES Millennia Music Media Systems 4200 B Day Spring Ct Placerville CA 95667 USA T 530 647 0750 F 9921 E MAIL info mil media com WEB http www mil media com This page can be downloaded fro...

Страница 12: ...CLUSIONS There are no express warranties except as listed above Millennia Media shall not be liable for special subsequent incidental consequential or punitive damages including but not limited to damage to recordings microphones mixing consoles or any associated equipment down time costs loss of goodwill or claims of any party dealing with purchaser for such damages re sulting from the use of thi...

Отзывы: