background image

TCL-2

TCL-2 REAR PANEL

(1) INPUTS  "In 1 (Left), In 2 (Right)"

Conventional 3-pin female XLR input jacks for all balanced or unbalanced line level signals. In-

put impedance is greater than 10k ohms when "10 dB" gain range switch is engaged (+/- 10dB), 
greater than 40k ohms when gain range switch is disengaged (+/- 20dB), and greater than 100k 

ohms when optional balanced inputs are installed. Standard TCL-2 line input is unbalanced us-
ing pin 1 as chassis ground, pin two as signal, and pin 3 tied to audio ground.  

(2) OUTPUTS  "Out 1 (Left), Out 2 (Right)"

Conventional 3-pin male XLR output jacks. Output is unbalanced. Pin 1 is chassis ground, pin 

2 is signal, and pin 3 is tied to audio ground. J-FET topology output impedance is 55 ohms. 
Vacuum tube output impedance is 150 ohms. 

(3) EARTH/AUDIO GROUND JUMPER 

A barrier terminal which ties earth ground to audio ground. If ground "hum" loops are experi-
enced when using the TCL-2, removing this jumper may help. Using this jumper, the integrity 
of the chassis/earth ground connection is never compromised. 

(4) AC VOLTAGE MAINS SELECTION  "100-120" or "200-240"

A power entry module with a removable fuse holder block. This fuse holder block is selectable 
for 100 to 120 Volt or 200 to 240 Volt worldwide mains powering. The fuse block contains two 
fuses — one fuse is in series with the hot power line while the other fuse is in series with the 
neutral power line. Both fuses must be installed. To change the mains voltage selection, remove 
IEC power connector and assure that the TCL-2 is not connected to mains power. With a non-
conductive tool, gently pry the fuse block away from the power entry module. Remove the 
two fuses and replace both with type as shown below. Slide out the internal PC Board, turn it 
over, and reinsert the PCB so that the desired AC mains voltage appears in the viewing window. 
Double check that the fuses installed correspond to the AC mains voltage range which appears 
in the viewing window. Gently push the fuse block back until flush and snug.

FUSES:
For 100-120 VAC mains, use 5x20mm, 1A, slow blow, 250V, Littelfuse 239 or equivalent.
For 200-240 VAC mains, use 5x20mm, 500 mA, slow blow, 250V, Littelfuse 239 or equivalent.

(5) POWER ENTRY  "IEC Power Receptacle"

An IEC-type AC line-power receptacle for use with removable cords. Use only the power cord 
provided with the TCL-2 unit or equivalent U/L approved type SV, SVT, SJ, or SJT AC power 
supply cord. Do not defeat the third pin earth ground! If ground lifting is desired, remove the 
Earth/Audio Ground Jumper strap (item number 3, above).

NOTE:  Units configured for 200-240 do not have a power cord included. Contact your dealer 
or distributor for a cable appropriate for your country.

Содержание TCL-2

Страница 1: ...l contained in this manual consists of information that is property of Millennia Media Inc and is intended solely for use by the purchasers of the equipment described in this manual Millennia Media Inc expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation and or maintenance of the equip ment described in this manual without th...

Страница 2: ... on or pinched by having objects placed on it Pay particular attention to plugs receptacles and the point where the AC power cord exits the TCL 2 4 GROUNDING For your safety it is extremely important that the grounding pin of the 3 wire power cable in cluded with unit be inserted into a grounding type 3 pin power outlet If you are unable to insert the plug into an existing outlet contact an electr...

Страница 3: ...ure that the rear panel voltage selection fuse block switch is set correctly In the USA the TCL 2 is shipped with the voltage selection block set to 100 120 VAC At this voltage setting a pair of 1 amp 5 x 20 mm slow blow fuses have been factory installed If you change the voltage selection block to 200 240 VAC usage be sure to change both fuses to 500 milliamp 0 4 amp slow blow types The TCL 2 enc...

Страница 4: ...The fuse block contains two fuses one fuse is in series with the hot power line while the other fuse is in series with the neutral power line Both fuses must be installed To change the mains voltage selection remove IEC power connector and assure that the TCL 2 is not connected to mains power With a non conductive tool gently pry the fuse block away from the power entry module Remove the two fuses...

Страница 5: ... TCL 2 1 2 4 5 3 GROUND LIFT PUSH PUSH 115 IN 2 OUT 2 IN 1 OUT 1 TCL 2 Twincom Rear Panel ______________ 1 2 4 5 3 ...

Страница 6: ...ch selects channel status When switch is depressed and corresponding LED is illuminated audio signal will be processed by dynamics functions When switch is not depressed and LED is not illuminated audio signal is not processed by dynamics functions This is not a hard wire bypass Audio signal is always in the active circuit path regardless of this switch s status 6 METER FUNCTION SELECT SWITCH METE...

Страница 7: ... TCL 2 TCL 2 Twincom Rear Panel ______________ ...

Страница 8: ... desired about of GR as shown on the meter E Depress the Stereo Link switch Note the amount of GR shown on the meter will probably decrease Simply increase the threshold until you again achieve the desired about of GR as shown on the meter F You should now see the same amount of GR on BOTH meters If you do not adjust the ratio control s on one or both channels until you do 10 METER ZERO ADJUST MET...

Страница 9: ... ohms VT or SS 5 ohms 300 ohms 300 ohms SS 3 000 ohms VT 87 dBu SS 82 dBu VT 50 dB 75 dB typical lOOmV to 20 kHz Pin 2 positive polarity Pin 1 ground 20 dBu to 20 dBu continuously adjustable 2 mS to 100 mS continuously adjustable 00 mS to 3 0 sec continuously adjustable Min 1 4 to 1 Max 30 to 1 continuous Yes Yes Yes Switch In FET Amplifiers Switch Out Vacuum Tube Amplifiers ELECTRO MECHANICAL SPE...

Страница 10: ... goal of absolute sonic neutrality and timbre purity 1 No audio transformers The vast majority of professional vacuum tube audio equipment uses audio transformers Yet as someone once said there is no transformer that sounds like no transformer For this reason Millennia avoids audio path transformers and relies on other less colorful coupling techniques 2 Lower tighter gain and threshold structure ...

Страница 11: ...PUT LEVEL OUTPUT LEVEL CH IN CH IN METER ON GR METER ON GR STEREO LINK TT TT VU 20 10 7 5 3 3 2 2 1 1 0 VU 20 10 7 5 3 3 2 2 1 1 0 Millennia Music Media Systems TCL 2 Template DATE PROJECT STUDIO ARTIST SONG LOG NOTES Millennia Music Media Systems 4200 B Day Spring Ct Placerville CA 95667 USA T 530 647 0750 F 9921 E MAIL info mil media com WEB http www mil media com This page can be downloaded fro...

Страница 12: ...CLUSIONS There are no express warranties except as listed above Millennia Media shall not be liable for special subsequent incidental consequential or punitive damages including but not limited to damage to recordings microphones mixing consoles or any associated equipment down time costs loss of goodwill or claims of any party dealing with purchaser for such damages re sulting from the use of thi...

Отзывы: