Millenium Signatures MS-510 Скачать руководство пользователя страница 7

THE MILLENNIUM SIGNATURES B-1220/B-2045 BENCH 

FIXTURESROLL MARKING APPLICATIONS

NOTE:

 To avoid short circuits (See illustration 1-A), do not cross the leads, or make 

contact between the marker and the grounded surface when both surfaces are bare.

DIRECTIONS:

A)

 Plug the black wire into the black jack of the bench fixture.

B)

 Remove the top plate (carbon) from the fixture.

C)

 Pour the recommended electrolyte into the well.

E)

 Replace the top plate.

F)

 Place a deep etch pad or monopad (blue side out) on the top plate, and secure it with 

the enclosed “O” ring.  Make certain that the sides of th pad are tucked down inside the 

well.  This will insure that your pad will draw the fluid without operator assistance.  Use 

either a B-1220-3, B-1220DE, B-2045-3, or a B-2045DE monopad for best results.

G)

 Place the stencil over the pad with the reading face down, as if to read the 

information from the bottom of the fixture.  Slide the “O” ring over the stencil pad and 

top plate until it snaps into the machined groove.

H)

 Connect the hand ground (flat bottom or knife edge) to the ground jack of your 

power unit.

I)

 Place the substrate (surface to be marked) on the stencil in front of the reading.  

Place the hand ground on the substrate, and roll the substrate over the reading, using 

moderate pressure.

J)

 Use Millennium Signatures’ neutralizer to neutralize any area of the substrate that 

has come into contact with the electrolyte.

K)

 For added protection, apply Millennium Signatures’ Rust Preventative Oil (RPO).  

It is always a good practice to apply oil to ensure rust and corrosion protection.

FOR ADDITIONAL INFORMATION CONTACT MILLENNIUM SIGNATURES  

Phone: (905) 639-0909 

Fax: (905) 639-0919 

E-mail: [email protected] 

THANK YOU!

Содержание MS-510

Страница 1: ...Model MS 510 Instruction Manual 4179 7 Harvester Road Burlington Ontario Canada L7L 5M4 Phone 905 639 0909 Fax 905 639 0919 E mail info millenniumsignatures com ...

Страница 2: ...ated from 0 2 to 2 4 seconds to automatically control power pulsing Foot Pedal Manual or Automatic Operator Selection High Power indicator light 2 3 0 Amp Fuses for power unit protection against overloading Smooth action Power Selection Switch Built in alarm to alert the operator of amperage overload Two individual Rotary Time Selectors NOTE Avoid short circuits See illustration 1 A Do not cross t...

Страница 3: ...ures 9 11 5 4 1 10 respectively Illustration 3 A Turn the power unit on Choose the proper current setting AC produces a black mark DC produces a white mark and is also used for deep etching A white mark may be desirable for etching various materials such as black oxide B The 510 B Power Unit is equipped with twelve power settings With the voltage switch Fig 5 set to LOW the settings on the POWER S...

Страница 4: ...ropriate monopad on the marking head and attach the insert stencil cap stencil or flat stencil as required E Place the long tube from the 152 electrolyte pump in the open bottle of electrolyte Prime the pump by rotating quickly clockwise The pump is adjusted by the small set screw on the stop below the lever SEMI AUTOMATIC OPERATION A Flip the power toggle switch up to turn the unit on B Choose th...

Страница 5: ...ON controls the length of time the current is delivered to the marking head The dial marked OFF controls the length of time the current flow is interrupted even through the marking head remains in contact with the substrate The greater the number the longer the times in both cases An amp meter FIG 8 has been provided for visual confirmation of the current These timers are used for applications tha...

Страница 6: ...main up for the selected time and then repeat this cycle until the machine is shut off HOUSEKEEPING It is important to keep your unit free of oxidation and salt build up This will ensure years of dependable trouble free operation A Keep the cord ends alligator plug marking heads and grounds clean If corrosion appears use a light abrasive such as an emery cloth to clean it off B To prevent corrosio...

Страница 7: ...DE monopad for best results G Place the stencil over the pad with the reading face down as if to read the information from the bottom of the fixture Slide the O ring over the stencil pad and top plate until it snaps into the machined groove H Connect the hand ground flat bottom or knife edge to the ground jack of your power unit I Place the substrate surface to be marked on the stencil in front of...

Отзывы: